Unknown

Dataset Information

0

New reagents for enhanced liquid chromatographic separation and charging of intact protein ions for electrospray ionization mass spectrometry.


ABSTRACT: Electrospray ionization produces multiply charged ions, thereby lowering the mass-to-charge ratio for peptides and small proteins to a range readily accessed by quadrupole ion trap, orbitrap, and ion cyclotron resonance (ICR) mass analyzers (m/z = 400-2000). For Fourier transform mass analyzers (orbitrap and ICR), higher charge also improves signal-to-noise ratio, mass resolution, and mass accuracy. Addition of m-nitrobenzyl alcohol (m-NBA) or sulfolane has previously been shown to increase the charge states of proteins. Moreover, polar aprotic dimethylformamide (DMF) improves chromatographic separation of proteolytic peptides for mass analysis of solution-phase protein hydrogen/deuterium exchange for improved (78-96%) sequence coverage. Here, we show that addition of each of the various modifiers (DMF, thiodiglycol, dimethylacetamide, dimethylsulfoxide, and N-methylpyrrolidone) can significantly increase the charge states of proteins up to 78 kDa. Moreover, incorporation of the same modifiers into reversed-phase liquid chromatography solvents improves sensitivity, charging, and chromatographic resolution for intact proteins.

SUBMITTER: Valeja SG 

PROVIDER: S-EPMC2932825 | biostudies-literature | 2010 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

New reagents for enhanced liquid chromatographic separation and charging of intact protein ions for electrospray ionization mass spectrometry.

Valeja Santosh G SG   Tipton Jeremiah D JD   Emmett Mark R MR   Marshall Alan G AG  

Analytical chemistry 20100901 17


Electrospray ionization produces multiply charged ions, thereby lowering the mass-to-charge ratio for peptides and small proteins to a range readily accessed by quadrupole ion trap, orbitrap, and ion cyclotron resonance (ICR) mass analyzers (m/z = 400-2000). For Fourier transform mass analyzers (orbitrap and ICR), higher charge also improves signal-to-noise ratio, mass resolution, and mass accuracy. Addition of m-nitrobenzyl alcohol (m-NBA) or sulfolane has previously been shown to increase the  ...[more]

Similar Datasets

| S-EPMC5518571 | biostudies-literature
| S-EPMC3901310 | biostudies-literature
| S-EPMC3769336 | biostudies-literature
| S-EPMC3770260 | biostudies-literature
| S-EPMC3277681 | biostudies-literature
| S-EPMC4617747 | biostudies-literature
| S-EPMC3290520 | biostudies-literature
| S-EPMC4551553 | biostudies-literature
| S-EPMC7588016 | biostudies-literature
| S-EPMC5017310 | biostudies-literature