Reversible detection of heparin and other polyanions by pulsed chronopotentiometric polymer membrane electrode.


ABSTRACT: The first fully reversible polymeric membrane-based sensor for the anticoagulant heparin and other polyanions using a pulsed chronopotentiometry (pulstrode) measurement mode is reported. Polymeric membranes containing a lipophilic inert salt of the form R(+)R(-) (where R(+) and R(-) are tridodecylmethylammonium (TDMA(+)) and dinonylnaphthalene sulfonate (DNNS(-)), respectively) are used to suppress unwanted spontaneous ion extractions under zero-current equilibrium conditions. An anodic galvanostatic current pulse applied across the membrane perturbs the equilibrium lipophilic ion distribution within the membrane phase in such a way that anions/polyanions are extracted into the membrane from the sample. The membrane is then subjected to an open-circuit zero current state for a short period, and finally a 0 V vs reference electrode potentiostatic pulse is applied to restore the membrane to its initial full equilibrium condition. Potentials are sampled as average values during the last 10% of the 0.5 s open circuit phase of the measurement cycle. Fully reversible and reproducible electromotive force (emf) responses are observed for heparin, pentosan polysulfate (PPS), chondroitin sulfate (CS), and oversulfated chondroitin sulfate (OSCS), with the magnitude of the potentiometric response proportional to charge density of the polyanions. The sensor provides an emf response related to heparin concentrations in the range of 1-20 U/mL. The responses to variations in heparin levels and toward other polyanions of the pulstrode configuration are analogous to the already established single-use, nonreversible potentiometric polyion sensors based on membranes doped only with the lipophilic anion exchanger TDMA(+).

SUBMITTER: Gemene KL 

PROVIDER: S-EPMC2992876 | biostudies-literature | 2010 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reversible detection of heparin and other polyanions by pulsed chronopotentiometric polymer membrane electrode.

Gemene Kebede L KL   Meyerhoff Mark E ME  

Analytical chemistry 20100301 5


The first fully reversible polymeric membrane-based sensor for the anticoagulant heparin and other polyanions using a pulsed chronopotentiometry (pulstrode) measurement mode is reported. Polymeric membranes containing a lipophilic inert salt of the form R(+)R(-) (where R(+) and R(-) are tridodecylmethylammonium (TDMA(+)) and dinonylnaphthalene sulfonate (DNNS(-)), respectively) are used to suppress unwanted spontaneous ion extractions under zero-current equilibrium conditions. An anodic galvanos  ...[more]

Similar Datasets

| S-EPMC7343805 | biostudies-literature
| S-EPMC10056398 | biostudies-literature
| S-EPMC6013769 | biostudies-literature
| S-EPMC1130523 | biostudies-other
| S-EPMC5571458 | biostudies-literature
| S-EPMC5808462 | biostudies-literature
| S-EPMC3249395 | biostudies-literature
| S-EPMC6614476 | biostudies-literature
| S-EPMC5414052 | biostudies-literature
| S-EPMC10993409 | biostudies-literature