Electrospray-assisted laser desorption ionization mass spectrometry (ELDI-MS) with an infrared laser for characterizing peptides and proteins.


ABSTRACT: An electrospray-assisted laser desorption/ionization source with an infrared OPO laser (IR-ELDI) was constructed and optimized for peptide and protein mass spectrometry analysis. Similar to ELDI with an ultraviolet laser, IR-ELDI generates multiply charged molecules for peptides and proteins measured under ambient sampling conditions. Both samples in the dried state and analyte solutions can be directly measured by IR-ELDI without the presence of a conventional MALDI matrix. However, the analysis of sample solutions is shown to greatly enhance the sensitivity of the mass spectrometry measurement, as a 100-fold sensitivity gain for peptide measurements was measured. The limit of detection of IR-ELDI was determined to be 250 fmol for bradykinin (1.1 kDa), 100 fmol for ubiquitin (8.6 kDa), and 500 fmol for carbonic anhydrase (29 kDa). IR-ELDI is amenable for MS and MSn analysis for proteins up to 80 kDa transferrin. IR-ELDI-MS may be a useful tool for protein sequencing analysis from complex biological matrices, with minimal sample preparation required.

SUBMITTER: Peng IX 

PROVIDER: S-EPMC3006438 | biostudies-literature | 2010 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electrospray-assisted laser desorption ionization mass spectrometry (ELDI-MS) with an infrared laser for characterizing peptides and proteins.

Peng Ivory X IX   Ogorzalek Loo Rachel R RR   Margalith Eli E   Little Mark W MW   Loo Joseph A JA  

The Analyst 20100401 4


An electrospray-assisted laser desorption/ionization source with an infrared OPO laser (IR-ELDI) was constructed and optimized for peptide and protein mass spectrometry analysis. Similar to ELDI with an ultraviolet laser, IR-ELDI generates multiply charged molecules for peptides and proteins measured under ambient sampling conditions. Both samples in the dried state and analyte solutions can be directly measured by IR-ELDI without the presence of a conventional MALDI matrix. However, the analysi  ...[more]

Similar Datasets

| S-EPMC8284694 | biostudies-literature
| S-EPMC5007172 | biostudies-literature
| S-EPMC9541130 | biostudies-literature
| S-EPMC9287052 | biostudies-literature
| S-EPMC8018523 | biostudies-literature
| S-EPMC3654692 | biostudies-literature
| S-EPMC5653407 | biostudies-literature
| S-EPMC4495968 | biostudies-literature
| S-EPMC9643617 | biostudies-literature
| S-EPMC9944128 | biostudies-literature