Dual-axis electron tomography of biological specimens: Extending the limits of specimen thickness with bright-field STEM imaging.


ABSTRACT: The absence of imaging lenses after the specimen in the scanning transmission electron microscope (STEM) enables electron tomography to be performed in the STEM mode on micrometer-thick plastic-embedded specimens without the deleterious effect of chromatic aberration, which limits spatial resolution and signal-to-noise ratio in conventional TEM. Using Monte Carlo calculations to simulate electron scattering from gold nanoparticles situated at the top and bottom surfaces of a plastic section, we assess the optimal acquisition strategy for axial bright-field STEM electron tomography at a beam-energy of 300keV. Dual tilt-axis STEM tomography with optimized axial bight-field detector geometry is demonstrated by application to micrometer-thick sections of beta cells from mouse pancreatic islet. The quality of the resulting three-dimensional reconstructions is comparable to that obtained from much thinner (0.3-micrometer) sections using conventional TEM tomography. The increased range of specimen thickness accessible to axial STEM tomography without the need for serial sectioning enables the 3-D visualization of more complex and larger subcellular structures.

SUBMITTER: Sousa AA 

PROVIDER: S-EPMC3056916 | biostudies-literature | 2011 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dual-axis electron tomography of biological specimens: Extending the limits of specimen thickness with bright-field STEM imaging.

Sousa Alioscka A AA   Azari Afrouz A AA   Zhang Guofeng G   Leapman Richard D RD  

Journal of structural biology 20101103 1


The absence of imaging lenses after the specimen in the scanning transmission electron microscope (STEM) enables electron tomography to be performed in the STEM mode on micrometer-thick plastic-embedded specimens without the deleterious effect of chromatic aberration, which limits spatial resolution and signal-to-noise ratio in conventional TEM. Using Monte Carlo calculations to simulate electron scattering from gold nanoparticles situated at the top and bottom surfaces of a plastic section, we  ...[more]

Similar Datasets

| S-EPMC4374707 | biostudies-literature
| S-EPMC7111319 | biostudies-literature
| S-EPMC5379191 | biostudies-literature
| S-EPMC6401162 | biostudies-literature
| S-EPMC5393621 | biostudies-literature
| S-EPMC8689146 | biostudies-literature
| S-EPMC5685650 | biostudies-literature
| S-EPMC4504751 | biostudies-literature
| S-EPMC6786485 | biostudies-literature