Reading with a simulated 60-channel implant.


ABSTRACT: First generation retinal prostheses containing 50-60 electrodes are currently in clinical trials. The purpose of this study was to evaluate the theoretical upper limit (best possible) reading performance attainable with a state-of-the-art 60-channel retinal implant and to find the optimum viewing conditions for the task. Four normal volunteers performed full-page text reading tasks with a low-resolution, 60-pixel viewing window that was stabilized in the central visual field. Two parameters were systematically varied: (1) spatial resolution (image magnification) and (2) the orientation of the rectangular viewing window. Performance was measured in terms of reading accuracy (% of correctly read words) and reading rates (words/min). Maximum reading performances were reached at spatial resolutions between 3.6 and 6 pixels/char. Performance declined outside this range for all subjects. In optimum viewing conditions (4.5 pixels/char), subjects achieved almost perfect reading accuracy and mean reading rates of 26 words/min for the vertical viewing window and of 34 words/min for the horizontal viewing window. These results suggest that, theoretically, some reading abilities can be restored with actual state-of-the-art retinal implant prototypes if "image magnification" is within an "optimum range." Future retinal implants providing higher pixel resolutions, thus allowing for a wider visual span might allow faster reading rates.

SUBMITTER: Fornos AP 

PROVIDER: S-EPMC3089939 | biostudies-literature | 2011

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reading with a simulated 60-channel implant.

Fornos Angélica Pérez AP   Sommerhalder Jörg J   Pelizzone Marco M  

Frontiers in neuroscience 20110502


First generation retinal prostheses containing 50-60 electrodes are currently in clinical trials. The purpose of this study was to evaluate the theoretical upper limit (best possible) reading performance attainable with a state-of-the-art 60-channel retinal implant and to find the optimum viewing conditions for the task. Four normal volunteers performed full-page text reading tasks with a low-resolution, 60-pixel viewing window that was stabilized in the central visual field. Two parameters were  ...[more]

Similar Datasets

| S-EPMC9035555 | biostudies-literature
| S-EPMC7298809 | biostudies-literature
| S-EPMC7177599 | biostudies-literature
| S-EPMC3954900 | biostudies-literature
| S-EPMC6144588 | biostudies-literature
| S-EPMC8525839 | biostudies-literature
| S-EPMC3494451 | biostudies-other
| S-EPMC10214678 | biostudies-literature
| S-EPMC3554620 | biostudies-literature
| S-EPMC4643061 | biostudies-literature