Low interrater reliability of examiners performing the prone instability test: a clinical test for lumbar shear instability.


ABSTRACT:

Objective

To test the interrater reliability of examiners performing the prone instability test (PIT), a clinical test proposed to identify lumbar shear instability.

Design

Cross-sectional test-retest design examining individuals with mechanical low back pain (LBP).

Setting

University-based musculoskeletal analysis laboratory.

Participants

Individuals (N=30) with mechanical LBP recruited from community sources in a metropolitan region.

Interventions

Not applicable.

Main outcome measures

Repeated measures of a clinical examination test proposed to identify lumbar shear instability.

Results

Interrater reliability of examiners' judgments of PIT results were indexed with percentage of agreement and ? statistic. Examiners obtained 63% agreement and ? of .10 (95% confidence interval, -.27 to .47). Adjusted ? values based on prevalence and bias indexes were calculated to evaluate the effect on ?. The prevalence index associated with examiner judgments of the PIT was .43, and bias index was .03. The prevalence-adjusted bias-adjusted ? value was slightly higher than the unadjusted ? value (?=.27; 95% confidence interval, -.08 to .61).

Conclusions

Results of our study are not consistent with those of previous studies examining the reliability of therapists performing the PIT. We conclude that examiners do not attain acceptable interrater reliability when performing procedures for the PIT based on the information currently provided in the literature. Based on our experience, we suggest further exploration, standardization, and clarification of procedural details to improve therapists' ability to conduct the PIT on individuals with LBP.

SUBMITTER: Ravenna MM 

PROVIDER: S-EPMC3104326 | biostudies-literature | 2011 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Low interrater reliability of examiners performing the prone instability test: a clinical test for lumbar shear instability.

Ravenna Margaret M MM   Hoffman Shannon L SL   Van Dillen Linda R LR  

Archives of physical medicine and rehabilitation 20110601 6


<h4>Objective</h4>To test the interrater reliability of examiners performing the prone instability test (PIT), a clinical test proposed to identify lumbar shear instability.<h4>Design</h4>Cross-sectional test-retest design examining individuals with mechanical low back pain (LBP).<h4>Setting</h4>University-based musculoskeletal analysis laboratory.<h4>Participants</h4>Individuals (N=30) with mechanical LBP recruited from community sources in a metropolitan region.<h4>Interventions</h4>Not applic  ...[more]