Unknown

Dataset Information

0

Early detection and treatment of wear particle-induced inflammation and bone loss in a mouse calvarial osteolysis model using HPMA copolymer conjugates.


ABSTRACT: Wear particle-induced inflammation is considered to be the major cause of aseptic implant loosening and clinical failure after total joint replacement. Due to the frequent absence of symptoms, early detection and intervention prior to implant failure presents a significant challenge. To address this issue, a N-(2-hydroxypropyl)methacrylamide (HPMA) copolymer-based optical imaging contrast agent (P-IRDye) was developed and used for the detection of wear particle-induced inflammation employing a murine calvaria osteolysis model. The particle-induced osteolysis of calvaria was evaluated by H&E, tartrate-resistant acid phosphatase (TRAP) staining and ?-CT after necropsy. One-day post particle implantation, P-IRDye was administrated to the mice via tail vein injection. Live imaging of the animals 6 days after implantation revealed the preferential distribution and sustained retention of the macromolecular contrast agent at the site of particle implantation. Immunohistochemical staining and FACS analyses of the calvaria-associated soft tissue revealed extensive uptake of the HPMA copolymer by F4/80, Ly-6G (Gr1) and CD11c positive cells, which accounts for the retention of the macromolecular probes at the inflammatory sites. To test the potential of the system for therapeutic intervention, an acid-labile HPMA copolymer-dexamethasone conjugate (P-Dex) was prepared and shown to prevent the particle-induced inflammation and bone damage in the calvaria osteolysis model.

SUBMITTER: Ren K 

PROVIDER: S-EPMC3148351 | biostudies-literature | 2011 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Early detection and treatment of wear particle-induced inflammation and bone loss in a mouse calvarial osteolysis model using HPMA copolymer conjugates.

Ren Ke K   Purdue P Edward PE   Burton Lyndsey L   Quan Ling-dong LD   Fehringer Edward V EV   Thiele Geoffrey M GM   Goldring Steven R SR   Wang Dong D  

Molecular pharmaceutics 20110412 4


Wear particle-induced inflammation is considered to be the major cause of aseptic implant loosening and clinical failure after total joint replacement. Due to the frequent absence of symptoms, early detection and intervention prior to implant failure presents a significant challenge. To address this issue, a N-(2-hydroxypropyl)methacrylamide (HPMA) copolymer-based optical imaging contrast agent (P-IRDye) was developed and used for the detection of wear particle-induced inflammation employing a m  ...[more]

Similar Datasets

| S-EPMC3386559 | biostudies-literature
| S-EPMC6779862 | biostudies-literature
| S-EPMC4631633 | biostudies-other
2023-06-17 | GSE234863 | GEO
| S-EPMC3572842 | biostudies-literature
| S-EPMC8883393 | biostudies-literature
| S-EPMC10582964 | biostudies-literature
| S-EPMC3324493 | biostudies-literature
| S-EPMC4299399 | biostudies-other
| S-EPMC4355312 | biostudies-literature