Unknown

Dataset Information

0

Tissue-engineered intervertebral discs produce new matrix, maintain disc height, and restore biomechanical function to the rodent spine.


ABSTRACT: Lower back and neck pain are leading physical conditions for which patients see their doctors in the United States. The organ commonly implicated in this condition is the intervertebral disc (IVD), which frequently herniates, ruptures, or tears, often causing pain and limiting spinal mobility. To date, approaches for replacement of diseased IVD have been confined to purely mechanical devices designed to either eliminate or enable flexibility of the diseased motion segment. Here we present the evaluation of a living, tissue-engineered IVD composed of a gelatinous nucleus pulposus surrounded by an aligned collagenous annulus fibrosus in the caudal spine of athymic rats for up to 6 mo. When implanted into the rat caudal spine, tissue-engineered IVD maintained disc space height, produced de novo extracellular matrix, and integrated into the spine, yielding an intact motion segment with dynamic mechanical properties similar to that of native IVD. These studies demonstrate the feasibility of engineering a functional spinal motion segment and represent a critical step in developing biological therapies for degenerative disc disease.

SUBMITTER: Bowles RD 

PROVIDER: S-EPMC3156186 | biostudies-literature | 2011 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Tissue-engineered intervertebral discs produce new matrix, maintain disc height, and restore biomechanical function to the rodent spine.

Bowles Robby D RD   Gebhard Harry H HH   Härtl Roger R   Bonassar Lawrence J LJ  

Proceedings of the National Academy of Sciences of the United States of America 20110801 32


Lower back and neck pain are leading physical conditions for which patients see their doctors in the United States. The organ commonly implicated in this condition is the intervertebral disc (IVD), which frequently herniates, ruptures, or tears, often causing pain and limiting spinal mobility. To date, approaches for replacement of diseased IVD have been confined to purely mechanical devices designed to either eliminate or enable flexibility of the diseased motion segment. Here we present the ev  ...[more]

Similar Datasets

| S-EPMC5650136 | biostudies-literature
| S-EPMC5699461 | biostudies-literature
2020-05-15 | GSE130561 | GEO
| S-EPMC3640714 | biostudies-literature
| S-EPMC9238288 | biostudies-literature
| S-EPMC7064427 | biostudies-literature