Unknown

Dataset Information

0

Using laboratory models to test treatment: morphine reduces dyspnea and hypercapnic ventilatory response.


ABSTRACT:

Rationale

Opioids are commonly used to relieve dyspnea, but clinical data are mixed and practice varies widely.

Objectives

Evaluate the effect of morphine on dyspnea and ventilatory drive under well-controlled laboratory conditions.

Methods

Six healthy volunteers received morphine (0.07 mg/kg) and placebo intravenously on separate days (randomized, blinded). We measured two responses to a CO(2) stimulus: (1) perceptual response (breathing discomfort; described by subjects as "air hunger") induced by increasing partial pressure of end-tidal carbon dioxide (Pet(CO2)) during restricted ventilation, measured with a visual analog scale (range, "neutral" to "intolerable"); and (2) ventilatory response, measured in separate trials during unrestricted breathing.

Measurements and main results

We determined the Pet(CO2) that produced a 60% breathing discomfort rating in each subject before morphine (median, 8.5 mm Hg above resting Pet(CO2)). At the same Pet(CO2) after morphine administration, median breathing discomfort was reduced by 65% of its pretreatment value; P < 0.001. Ventilation fell 28% at the same Pet(CO2); P < 0.01. The effect of morphine on breathing discomfort was not significantly correlated with the effect on ventilatory response. Placebo had no effect.

Conclusions

(1) A moderate morphine dose produced substantial relief of laboratory dyspnea, with a smaller reduction of ventilation. (2) In contrast to an earlier laboratory model of breathing effort, this laboratory model of air hunger established a highly significant treatment effect consistent in magnitude with clinical studies of opioids. Laboratory studies require fewer subjects and enable physiological measurements that are difficult to make in a clinical setting. Within-subject comparison of the response to carefully controlled laboratory stimuli can be an efficient means to optimize treatments before clinical trials.

SUBMITTER: Banzett RB 

PROVIDER: S-EPMC3208656 | biostudies-literature | 2011 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Using laboratory models to test treatment: morphine reduces dyspnea and hypercapnic ventilatory response.

Banzett Robert B RB   Adams Lewis L   O'Donnell Carl R CR   Gilman Sean A SA   Lansing Robert W RW   Schwartzstein Richard M RM  

American journal of respiratory and critical care medicine 20110721 8


<h4>Rationale</h4>Opioids are commonly used to relieve dyspnea, but clinical data are mixed and practice varies widely.<h4>Objectives</h4>Evaluate the effect of morphine on dyspnea and ventilatory drive under well-controlled laboratory conditions.<h4>Methods</h4>Six healthy volunteers received morphine (0.07 mg/kg) and placebo intravenously on separate days (randomized, blinded). We measured two responses to a CO(2) stimulus: (1) perceptual response (breathing discomfort; described by subjects a  ...[more]

Similar Datasets

| S-EPMC5207520 | biostudies-literature
| S-EPMC6451387 | biostudies-literature
| S-EPMC6276783 | biostudies-literature
| S-EPMC10858557 | biostudies-literature
| S-EPMC9804720 | biostudies-literature
| S-EPMC3718325 | biostudies-other
| S-EPMC10278984 | biostudies-literature
| S-EPMC5558540 | biostudies-literature
| S-EPMC3663820 | biostudies-other