A multi-dataset data-collection strategy produces better diffraction data.


ABSTRACT: A multi-dataset (MDS) data-collection strategy is proposed and analyzed for macromolecular crystal diffraction data acquisition. The theoretical analysis indicated that the MDS strategy can reduce the standard deviation (background noise) of diffraction data compared with the commonly used single-dataset strategy for a fixed X-ray dose. In order to validate the hypothesis experimentally, a data-quality evaluation process, termed a readiness test of the X-ray data-collection system, was developed. The anomalous signals of sulfur atoms in zinc-free insulin crystals were used as the probe to differentiate the quality of data collected using different data-collection strategies. The data-collection results using home-laboratory-based rotating-anode X-ray and synchrotron X-ray systems indicate that the diffraction data collected with the MDS strategy contain more accurate anomalous signals from sulfur atoms than the data collected with a regular data-collection strategy. In addition, the MDS strategy offered more advantages with respect to radiation-damage-sensitive crystals and better usage of rotating-anode as well as synchrotron X-rays.

SUBMITTER: Liu ZJ 

PROVIDER: S-EPMC3211246 | biostudies-literature | 2011 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

A multi-dataset data-collection strategy produces better diffraction data.

Liu Zhi Jie ZJ   Chen Lirong L   Wu Dong D   Ding Wei W   Zhang Hua H   Zhou Weihong W   Fu Zheng Qing ZQ   Wang Bi Cheng BC  

Acta crystallographica. Section A, Foundations of crystallography 20111018 Pt 6


A multi-dataset (MDS) data-collection strategy is proposed and analyzed for macromolecular crystal diffraction data acquisition. The theoretical analysis indicated that the MDS strategy can reduce the standard deviation (background noise) of diffraction data compared with the commonly used single-dataset strategy for a fixed X-ray dose. In order to validate the hypothesis experimentally, a data-quality evaluation process, termed a readiness test of the X-ray data-collection system, was developed  ...[more]

Similar Datasets

| S-EPMC4784673 | biostudies-literature
| S-EPMC3831301 | biostudies-literature
| S-EPMC5094441 | biostudies-literature
| S-EPMC4704080 | biostudies-other
| S-EPMC10869167 | biostudies-literature
| S-EPMC3851287 | biostudies-literature
| S-EPMC6091241 | biostudies-literature
| S-EPMC2756169 | biostudies-literature
| S-EPMC10187334 | biostudies-literature
| S-EPMC5182019 | biostudies-literature