Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators.


ABSTRACT: The safety and clinical utility of MRI at 1.5 T in patients with cardiac implantable devices such as pacemakers (PM) and implantable cardioverter-defibrillators (ICD) have been reported. This study aims to evaluate the extent of artifacts on cardiac magnetic resonance (CMR) in patients with PM and ICD (PM/ICD).A total of 71 CMR studies were performed with an established safety protocol in patients with prepectoral PM/ICD. The artifact area around the PM/ICD generator was measured in all short-axis (SA), horizontal (HLA), and vertical long-axis (VLA) SSFP cine planes. The location and extent of artifacts were also assessed in all SA (20 sectors per plane), HLA, and VLA (6 sectors per plane) late gadolinium-enhanced CMR (LGE-CMR) planes. The artifact area on cine CMR was significantly larger with ICD versus PM generators in each plane (P<0.001, respectively). In patients with left-sided ICD or biventricular ICD systems, the percentages of sectors with any artifacts on LGE-CMR were 53.7%, 48.0%, and 49.2% in SA, HLA, and VLA planes, respectively. Patients with left-sided PM or right-sided PM/ICD had fewer artifacts. Anterior and apical regions were severely affected by artifact caused by left-sided PM/ICD generators.In contrast to patients with right-sided PM/ICD and left-sided PM, the anterior and apical left ventricle can be affected by susceptibility artifacts in patients with left-sided ICD. Artifact reduction methodologies will be necessary to improve the performance of CMR in patients with left sided ICD systems.

SUBMITTER: Sasaki T 

PROVIDER: S-EPMC3218212 | biostudies-literature | 2011 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators.

Sasaki Takeshi T   Hansford Rozann R   Zviman Menekhem M MM   Kolandaivelu Aravindan A   Bluemke David A DA   Berger Ronald D RD   Calkins Hugh H   Halperin Henry R HR   Nazarian Saman S  

Circulation. Cardiovascular imaging 20110923 6


<h4>Background</h4>The safety and clinical utility of MRI at 1.5 T in patients with cardiac implantable devices such as pacemakers (PM) and implantable cardioverter-defibrillators (ICD) have been reported. This study aims to evaluate the extent of artifacts on cardiac magnetic resonance (CMR) in patients with PM and ICD (PM/ICD).<h4>Methods and results</h4>A total of 71 CMR studies were performed with an established safety protocol in patients with prepectoral PM/ICD. The artifact area around th  ...[more]

Similar Datasets

| S-EPMC6325447 | biostudies-literature
| S-EPMC5350419 | biostudies-literature
| S-EPMC2686319 | biostudies-other
| S-EPMC3410556 | biostudies-literature
| S-EPMC2875184 | biostudies-literature
| S-EPMC7569536 | biostudies-literature
| S-EPMC3526187 | biostudies-literature
| S-EPMC7212569 | biostudies-literature
| S-EPMC6816602 | biostudies-literature
| S-EPMC5561722 | biostudies-other