Unknown

Dataset Information

0

Accuracy of urine circulating cathodic antigen (CCA) test for Schistosoma mansoni diagnosis in different settings of Cote d'Ivoire.


ABSTRACT:

Background

Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis.

Methodology

We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A and B are endemic for S. mansoni, whereas S. haematobium co-exists in setting C. Overall, 446 children, aged 8-12 years, submitted multiple stool and urine samples. For S. mansoni diagnosis, stool samples were examined with triplicate Kato-Katz, whereas urine samples were tested with CCA-A. The first stool and urine samples were additionally subjected to an ether-concentration technique and CCA-B, respectively. Urine samples were examined for S. haematobium using a filtration method, and for microhematuria using Hemastix dipsticks.

Principal findings

Considering nine Kato-Katz as diagnostic 'gold' standard, the prevalence of S. mansoni in setting A, B and C was 32.9%, 53.1% and 91.8%, respectively. The sensitivity of triplicate Kato-Katz from the first stool and a single CCA-A test was 47.9% and 56.3% (setting A), 73.9% and 69.6% (setting B), and 94.2% and 89.6% (setting C). The respective sensitivity of a single CCA-B was 10.4%, 29.9% and 75.0%. The ether-concentration technique showed a low sensitivity for S. mansoni diagnosis (8.3-41.0%). The specificity of CCA-A was moderate (76.9-84.2%); CCA-B was high (96.7-100%). The likelihood of a CCA-A color reaction increased with higher S. mansoni fecal egg counts (odds ratio: 1.07, p<0.001). A concurrent S. haematobium infection or the presence of microhematuria did not influence the CCA-A test results for S. mansoni diagnosis.

Conclusion/significance

CCA-A showed similar sensitivity than triplicate Kato-Katz for S. mansoni diagnosis with no cross-reactivity to S. haematobium and microhematuria. The low sensitivity of CCA-B in our study area precludes its use for S. mansoni diagnosis.

SUBMITTER: Coulibaly JT 

PROVIDER: S-EPMC3222626 | biostudies-literature | 2011 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of urine circulating cathodic antigen (CCA) test for Schistosoma mansoni diagnosis in different settings of Côte d'Ivoire.

Coulibaly Jean T JT   Knopp Stefanie S   N'Guessan Nicaise A NA   Silué Kigbafori D KD   Fürst Thomas T   Lohourignon Laurent K LK   Brou Jean K JK   N'Gbesso Yve K YK   Vounatsou Penelope P   N'Goran Eliézer K EK   Utzinger Jürg J  

PLoS neglected tropical diseases 20111122 11


<h4>Background</h4>Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis.<h4>Methodology</h4>We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A and B are endemic for S. mansoni, whereas S. haematobium co-exists in setting C. Overall,  ...[more]

Similar Datasets

| S-EPMC3605147 | biostudies-literature
| S-EPMC7333430 | biostudies-literature
| S-EPMC8312929 | biostudies-literature
| S-EPMC4270510 | biostudies-literature
| S-EPMC3026766 | biostudies-literature
| S-EPMC5361543 | biostudies-literature
| S-EPMC7360052 | biostudies-literature
| S-EPMC4709075 | biostudies-literature
| S-EPMC7112237 | biostudies-literature
| S-EPMC7356434 | biostudies-literature