Unknown

Dataset Information

0

Optimal fine ?-slicing for single-photon-counting pixel detectors.


ABSTRACT: The data-collection parameters used in a macromolecular diffraction experiment have a strong impact on data quality. A careful choice of parameters leads to better data and can make the difference between success and failure in phasing attempts, and will also result in a more accurate atomic model. The selection of parameters has to account for the application of the data in various phasing methods or high-resolution refinement. Furthermore, experimental factors such as crystal characteristics, available experiment time and the properties of the X-ray source and detector have to be considered. For many years, CCD detectors have been the prevalent type of detectors used in macromolecular crystallography. Recently, hybrid pixel X-ray detectors that operate in single-photon-counting mode have become available. These detectors have fundamentally different characteristics compared with CCD detectors and different data-collection strategies should be applied. Fine ?-slicing is a strategy that is particularly well suited to hybrid pixel detectors because of the fast readout time and the absence of readout noise. A large number of data sets were systematically collected from crystals of four different proteins in order to investigate the benefit of fine ?-slicing on data quality with a noise-free detector. The results show that fine ?-slicing can substantially improve scaling statistics and anomalous signal provided that the rotation angle is comparable to half the crystal mosaicity.

SUBMITTER: Mueller M 

PROVIDER: S-EPMC3245722 | biostudies-literature | 2012 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optimal fine φ-slicing for single-photon-counting pixel detectors.

Mueller Marcus M   Wang Meitian M   Schulze-Briese Clemens C  

Acta crystallographica. Section D, Biological crystallography 20111209 Pt 1


The data-collection parameters used in a macromolecular diffraction experiment have a strong impact on data quality. A careful choice of parameters leads to better data and can make the difference between success and failure in phasing attempts, and will also result in a more accurate atomic model. The selection of parameters has to account for the application of the data in various phasing methods or high-resolution refinement. Furthermore, experimental factors such as crystal characteristics,  ...[more]

Similar Datasets

| S-EPMC7289839 | biostudies-literature
| S-EPMC3786515 | biostudies-other
| S-EPMC8596580 | biostudies-literature
| S-EPMC4650679 | biostudies-literature
| S-EPMC5297903 | biostudies-other
| S-EPMC3316693 | biostudies-other
| S-EPMC3060934 | biostudies-other
| S-EPMC7555505 | biostudies-literature
| S-EPMC4585911 | biostudies-literature
| S-EPMC2830710 | biostudies-literature