Image-guided drug delivery with magnetic resonance guided high intensity focused ultrasound and temperature sensitive liposomes in a rabbit Vx2 tumor model.


ABSTRACT: Clinical-grade doxorubicin encapsulated low temperature sensitive liposomes (LTSLs) were combined with a clinical magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) platform to investigate in vivo image-guided drug delivery. Plasma pharmacokinetics were determined in 3 rabbits. Fifteen rabbits with Vx2 tumors within superficial thigh muscle were randomly assigned into three treatment groups: 1) free doxorubicin, 2) LTSL and 3) LTSL + MR-HIFU. For the LTSL + MR-HIFU group, mild hyperthermia (40-41 °C) was applied to the tumors using an MR-HIFU system. Image-guided non-invasive hyperthermia was applied for a total of 30 min, completed within 1h after LTSL infusion. High-pressure liquid chromatography (HPLC) analysis of the harvested tumor and organ/tissue homogenates was performed to determine doxorubicin concentration. Fluorescence microscopy was performed to determine doxorubicin spatial distribution in the tumors. Sonication of Vx2 tumors resulted in accurate (mean = 40.5 ± 0.1 °C) and spatially homogenous (SD = 1.0 °C) temperature control in the target region. LTSL + MR-HIFU resulted in significantly higher tumor doxorubicin concentrations (7.6- and 3.4-fold greater compared to free doxorubicin and LTSL respectively, p<0.05, Newman-Keuls). This improved tumor concentration was achieved despite heating <25% of the tumor volume. Free doxorubicin and LTSL treatments appeared to deliver more drug in the tumor periphery as compared to the tumor core. In contrast, LTSL + MR-HIFU treatment suggested an improved distribution with doxorubicin found in both the tumor periphery and core. Doxorubicin bio-distribution in non-tumor organs/tissues was fairly similar between treatment groups. This technique has potential for clinical translation as an image-guided method to deliver drug to a solid tumor.

SUBMITTER: Ranjan A 

PROVIDER: S-EPMC3319290 | biostudies-literature | 2012 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Image-guided drug delivery with magnetic resonance guided high intensity focused ultrasound and temperature sensitive liposomes in a rabbit Vx2 tumor model.

Ranjan Ashish A   Jacobs Genevieve C GC   Woods David L DL   Negussie Ayele H AH   Partanen Ari A   Yarmolenko Pavel S PS   Gacchina Carmen E CE   Sharma Karun V KV   Frenkel Victor V   Wood Bradford J BJ   Dreher Matthew R MR  

Journal of controlled release : official journal of the Controlled Release Society 20111221 3


Clinical-grade doxorubicin encapsulated low temperature sensitive liposomes (LTSLs) were combined with a clinical magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) platform to investigate in vivo image-guided drug delivery. Plasma pharmacokinetics were determined in 3 rabbits. Fifteen rabbits with Vx2 tumors within superficial thigh muscle were randomly assigned into three treatment groups: 1) free doxorubicin, 2) LTSL and 3) LTSL + MR-HIFU. For the LTSL + MR-HIFU group, mild  ...[more]

Similar Datasets

| S-EPMC3417228 | biostudies-literature
| S-EPMC5907801 | biostudies-literature
| S-EPMC6047512 | biostudies-literature
| S-EPMC4568448 | biostudies-literature
| S-EPMC3249029 | biostudies-literature
| S-EPMC3237413 | biostudies-literature
| S-EPMC6005948 | biostudies-literature
| S-EPMC4121456 | biostudies-literature
| S-EPMC7407595 | biostudies-literature
| S-EPMC5474813 | biostudies-other