Clinical outcomes after treatment of multiple lesions with zotarolimus-eluting versus sirolimus-eluting coronary stents (a SORT OUT III substudy).
Ontology highlight
ABSTRACT: Data on clinical outcomes among patients treated with the zotarolimus-eluting Endeavor™ stent versus the sirolimus-eluting Cypher™ stent favor the sirolimus-eluting stent. However, a separate comparison of clinical outcome among patients treated for multiple lesions with these stents is lacking. We performed this comparison within the SORT OUT III trial data set.Among 2332 patients randomized in SORT OUT III, 695 were treated for multiple lesions with zotarolimus-eluting (n = 350) or sirolimus-eluting (n = 345) stents and followed for 18 months. Major adverse cardiac events (MACE); composite of cardiac death, myocardial infarction, or target vessel revascularization (TVR); was the primary endpoint.Zotarolimus-eluting compared to sirolimus-eluting stent treatment was associated with increased MACE rate (13.2% vs. 2.6%; hazard ratio 5.29 with 95% confidence interval: 2.59-10.8). All secondary endpoints; all cause death, cardiac death, myocardial infarction, TVR, target lesion revascularization, in-stent restenosis, and definite stent thrombosis; were observed more frequently among zotarolimus-eluting stent treated patients. For all endpoints, hazard ratios were 1.6 to 4.6 times higher than in the overall results of the SORT OUT III trial.We observed better clinical outcomes among patients treated for multiple lesions with the sirolimus-eluting stent compared to those treated with the zotarolimus-eluting stent.
SUBMITTER: Thim T
PROVIDER: S-EPMC3325867 | biostudies-literature | 2012 Mar
REPOSITORIES: biostudies-literature