Unknown

Dataset Information

0

Dielectrophoretic tweezers as a platform for molecular force spectroscopy in a highly parallel format.


ABSTRACT: We demonstrated the application of a simple electrode geometry for dielectrophoresis (DEP) on colloidal probes as a form of molecular force spectroscopy in a highly parallel format. The electric field between parallel plates is perturbed with dielectric microstructures, generating uniform DEP forces on colloidal probes in the range of several hundred piconewtons across a macroscopic sample area. We determined the approximate crossover frequency between negative and positive DEP using electrodes without dielectric microstructures-a simplification over standard experimental methods involving quadrupoles or optical trapping. 2D and 3D simulations of the electric field distributions validated the experimental behavior of several of our DEP tweezers geometries and provided insight into potential improvements. We applied the DEP tweezers to the stretching of a short DNA oligomer and detected its extension using total-internal reflection fluorescence microscopy. The combination of a simple cell fabrication, a uniform distribution of high axial forces, and a facile optical detection of our DEP tweezers makes this form of molecular force spectroscopy ideal for highly parallel detection of stretching or unbinding kinetics of biomolecules.

SUBMITTER: Cheng P 

PROVIDER: S-EPMC3383857 | biostudies-literature | 2011 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dielectrophoretic tweezers as a platform for molecular force spectroscopy in a highly parallel format.

Cheng Peng P   Barrett Michael J MJ   Oliver Piercen M PM   Cetin Deniz D   Vezenov Dmitri D  

Lab on a chip 20111103 24


We demonstrated the application of a simple electrode geometry for dielectrophoresis (DEP) on colloidal probes as a form of molecular force spectroscopy in a highly parallel format. The electric field between parallel plates is perturbed with dielectric microstructures, generating uniform DEP forces on colloidal probes in the range of several hundred piconewtons across a macroscopic sample area. We determined the approximate crossover frequency between negative and positive DEP using electrodes  ...[more]

Similar Datasets

| S-EPMC6210972 | biostudies-literature
| S-EPMC3397402 | biostudies-literature
| S-EPMC3491705 | biostudies-literature
| S-EPMC5709377 | biostudies-literature
| S-EPMC7316190 | biostudies-literature
| S-EPMC1276867 | biostudies-literature
| S-EPMC8779967 | biostudies-literature
| S-EPMC7335913 | biostudies-literature
| S-EPMC3389265 | biostudies-literature
| S-EPMC6546592 | biostudies-literature