Unknown

Dataset Information

0

Modelling and detecting tumour oxygenation levels.


ABSTRACT: Tumours that are low in oxygen (hypoxic) tend to be more aggressive and respond less well to treatment. Knowing the spatial distribution of oxygen within a tumour could therefore play an important role in treatment planning, enabling treatment to be targeted in such a way that higher doses of radiation are given to the more radioresistant tissue. Mapping the spatial distribution of oxygen in vivo is difficult. Radioactive tracers that are sensitive to different levels of oxygen are under development and in the early stages of clinical use. The concentration of these tracer chemicals can be detected via positron emission tomography resulting in a time dependent concentration profile known as a tissue activity curve (TAC). Pharmaco-kinetic models have then been used to deduce oxygen concentration from TACs. Some such models have included the fact that the spatial distribution of oxygen is often highly inhomogeneous and some have not. We show that the oxygen distribution has little impact on the form of a TAC; it is only the mean oxygen concentration that matters. This has significant consequences both in terms of the computational power needed, and in the amount of information that can be deduced from TACs.

SUBMITTER: Skeldon AC 

PROVIDER: S-EPMC3386285 | biostudies-literature | 2012

REPOSITORIES: biostudies-literature

altmetric image

Publications

Modelling and detecting tumour oxygenation levels.

Skeldon Anne C AC   Chaffey Gary G   Lloyd David J B DJ   Mohan Vineet V   Bradley David A DA   Nisbet Andrew A  

PloS one 20120628 6


Tumours that are low in oxygen (hypoxic) tend to be more aggressive and respond less well to treatment. Knowing the spatial distribution of oxygen within a tumour could therefore play an important role in treatment planning, enabling treatment to be targeted in such a way that higher doses of radiation are given to the more radioresistant tissue. Mapping the spatial distribution of oxygen in vivo is difficult. Radioactive tracers that are sensitive to different levels of oxygen are under develop  ...[more]

Similar Datasets

| S-EPMC4467376 | biostudies-literature
| S-EPMC7428026 | biostudies-literature
| S-EPMC6378184 | biostudies-literature
| S-EPMC7455028 | biostudies-literature
| PRJEB49976 | ENA
| S-EPMC6284397 | biostudies-literature
| S-EPMC6545061 | biostudies-literature
| S-EPMC7509680 | biostudies-literature
| S-EPMC3037282 | biostudies-literature
| S-EPMC3567468 | biostudies-literature