Unknown

Dataset Information

0

Human lamina cribrosa insertion and age.


ABSTRACT:

Purpose

To test the hypothesis that in healthy human eyes the lamina cribrosa (LC) insertion into the pia mater increases with age.

Methods

The optic nerve heads (ONHs) of donor eyes fixed at either 5 or 50 mm Hg of IOP were sectioned, stained, and imaged under bright- and dark-field conditions. A 3-dimensional (3D) model of each ONH was reconstructed. From the 3D models we measured the area of LC insertion into the peripapillary scleral flange and into the pia, and computed the total area of insertion and fraction of LC inserting into the pia. Linear mixed effect models were used to determine if the measurements were associated with age or IOP.

Results

We analyzed 21 eyes from 11 individuals between 47 and 91 years old. The LC inserted into the pia in all eyes. The fraction of LC inserting into the pia (2.2%-29.6%) had a significant decrease with age (P = 0.049), which resulted from a nonsignificant increase in the total area of LC insertion (P = 0.41) and a nonsignificant decrease in the area of LC insertion into the pia (P = 0.55). None of the measures was associated with fixation IOP (P values 0.44-0.81). Differences between fellow eyes were smaller than differences between unrelated eyes.

Conclusions

The LC insertion into the pia mater is common in middle-aged and older eyes, and does not increase with age. The biomechanical and vascular implications of the LC insertion into the pia mater are not well understood and should be investigated further.

SUBMITTER: Sigal IA 

PROVIDER: S-EPMC3466065 | biostudies-literature | 2012 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Human lamina cribrosa insertion and age.

Sigal Ian A IA   Flanagan John G JG   Lathrop Kira L KL   Tertinegg Inka I   Bilonick Richard R  

Investigative ophthalmology & visual science 20121003 11


<h4>Purpose</h4>To test the hypothesis that in healthy human eyes the lamina cribrosa (LC) insertion into the pia mater increases with age.<h4>Methods</h4>The optic nerve heads (ONHs) of donor eyes fixed at either 5 or 50 mm Hg of IOP were sectioned, stained, and imaged under bright- and dark-field conditions. A 3-dimensional (3D) model of each ONH was reconstructed. From the 3D models we measured the area of LC insertion into the peripapillary scleral flange and into the pia, and computed the t  ...[more]

Similar Datasets

| S-EPMC6491605 | biostudies-literature
| S-EPMC7174329 | biostudies-literature
| S-EPMC4815695 | biostudies-literature
| S-EPMC6370828 | biostudies-literature
| S-EPMC8542639 | biostudies-literature
| S-EPMC9202842 | biostudies-literature
| S-EPMC5940889 | biostudies-other
| S-EPMC6545820 | biostudies-literature
| S-EPMC6053916 | biostudies-literature
| S-EPMC7286041 | biostudies-literature