ABSTRACT: Purpose
To compare corneal endothelial cell density (ECD) and morphology between flap creation with a femtosecond laser and flap creation with a mechanical microkeratome 5 years after laser in situ keratomileusis (LASIK).Setting
Mayo Clinic, Rochester, Minnesota, USA.Design
Prospective randomized masked paired-eye study.Methods
In this study of LASIK for myopia or myopic astigmatism, fellow eyes were randomized by ocular dominance to flap creation by a femtosecond laser or by a mechanical microkeratome. Central endothelial images were analyzed before and 3 years and 5 years after LASIK; endothelial cell variables were compared between treatments at each examination. Relationships between endothelial cell loss and contact lens wear, residual bed thickness, and preoperative refractive error were evaluated.Results
There were no differences in the ECD, percentage of hexagonal cells, or coefficient of variation of cell area between treatments at any examination (all P = .99); the smallest detectable differences were 120 cells/mm(2), 5%, and 2%, respectively. The mean annual rate of corneal endothelial cell loss was -0.1% ± 1.2% (SD) and -0.1% ± 1.0% for the femtosecond laser and the mechanical microkeratome, respectively. Endothelial cell loss was not associated with contact lens wear, residual bed thickness, or preoperative refractive error.Conclusions
The energy delivered to the cornea during femtosecond laser flap creation did not affect the corneal endothelium 5 years after LASIK when compared with flap creation with a mechanical microkeratome. Corneas that have had either method of flap creation could be accepted as donor tissue for endothelial keratoplasty from the standpoint of endothelial health.Financial disclosure
No author has a financial or proprietary interest in any material or method mentioned.
SUBMITTER: Klingler KN
PROVIDER: S-EPMC3511658 | biostudies-literature | 2012 Dec
REPOSITORIES: biostudies-literature
Journal of cataract and refractive surgery 20121013 12
<h4>Purpose</h4>To compare corneal endothelial cell density (ECD) and morphology between flap creation with a femtosecond laser and flap creation with a mechanical microkeratome 5 years after laser in situ keratomileusis (LASIK).<h4>Setting</h4>Mayo Clinic, Rochester, Minnesota, USA.<h4>Design</h4>Prospective randomized masked paired-eye study.<h4>Methods</h4>In this study of LASIK for myopia or myopic astigmatism, fellow eyes were randomized by ocular dominance to flap creation by a femtosecond ...[more]