A comparative effectiveness analysis of three continuous glucose monitors.


ABSTRACT: To compare three continuous glucose monitoring (CGM) devices in subjects with type 1 diabetes under closed-loop blood glucose (BG) control.Six subjects with type 1 diabetes (age 52 ± 14 years, diabetes duration 32 ± 14 years) each participated in two 51-h closed-loop BG control experiments in the hospital. Venous plasma glucose (PG) measurements (GlucoScout, International Biomedical) obtained every 15 min (2,360 values) were paired in time with corresponding CGM glucose (CGMG) measurements obtained from three CGM devices, the Navigator (Abbott Diabetes Care), the Seven Plus (DexCom), and the Guardian (Medtronic), worn simultaneously by each subject. Errors in paired PG-CGMG measurements and data reporting percentages were obtained for each CGM device.The Navigator had the best overall accuracy, with an aggregate mean absolute relative difference (MARD) of all paired points of 11.8 ± 11.1% and an average MARD across all 12 experiments of 11.8 ± 3.8%. The Seven Plus and Guardian produced aggregate MARDs of all paired points of 16.5 ± 17.8% and 20.3 ± 18.0%, respectively, and average MARDs across all 12 experiments of 16.5 ± 6.7% and 20.2 ± 6.8%, respectively. Data reporting percentages, a measure of reliability, were 76% for the Seven Plus and nearly 100% for the Navigator and Guardian.A comprehensive head-to-head-to-head comparison of three CGM devices for BG values from 36 to 563 mg/dL revealed marked differences in performance characteristics that include accuracy, precision, and reliability. The Navigator outperformed the other two in these areas.

SUBMITTER: Damiano ER 

PROVIDER: S-EPMC3554299 | biostudies-literature | 2013 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

A comparative effectiveness analysis of three continuous glucose monitors.

Damiano Edward R ER   El-Khatib Firas H FH   Zheng Hui H   Nathan David M DM   Russell Steven J SJ  

Diabetes care 20121228 2


<h4>Objective</h4>To compare three continuous glucose monitoring (CGM) devices in subjects with type 1 diabetes under closed-loop blood glucose (BG) control.<h4>Research design and methods</h4>Six subjects with type 1 diabetes (age 52 ± 14 years, diabetes duration 32 ± 14 years) each participated in two 51-h closed-loop BG control experiments in the hospital. Venous plasma glucose (PG) measurements (GlucoScout, International Biomedical) obtained every 15 min (2,360 values) were paired in time wi  ...[more]

Similar Datasets

| S-EPMC5951038 | biostudies-literature
| S-EPMC10421863 | biostudies-literature
| S-EPMC3219278 | biostudies-other
| S-EPMC2875442 | biostudies-literature
| S-EPMC4764227 | biostudies-literature
| S-EPMC5588827 | biostudies-other
| S-EPMC7645140 | biostudies-literature
| S-EPMC10371100 | biostudies-literature
| S-EPMC7528568 | biostudies-literature
| S-EPMC5601025 | biostudies-literature