ARFI elastography in patients with chronic autoimmune liver diseases: A preliminary study.


ABSTRACT: OBJECTIVE: Acoustic radiation force impulse (ARFI) is a new software-based technique that evaluates liver stiffness during B-mode ultrasonography. The purpose of this study was to evaluate the accuracy of ARFI in distinguishing patients with chronic autoimmune liver disease from healthy subjects. MATERIAL AND METHODS: We enrolled 9 adult patients (8 women, 1 man; age 48.1 ± 12.8 years) with chronic autoimmune disease (primary biliary cirrhosis (PBC, n = 3), autoimmune hepatitis (AIH, n = 2), primary sclerosing cholangitis (PSC, n = 1) and overlap syndromes, (n = 3) who underwent a liver biopsy and 11 healthy volunteers (age 34.7 ± 10.4 years; 7 women, 4 men). Liver stiffness was evaluated and expressed as the shear wave velocity (SWV) in m/sec. We used a US scanner Siemens-Acuson S2000, evaluating the right liver lobe and the left liver lobe. RESULTS: THE SWV WAS SIGNIFICANTLY HIGHER IN CASES (RIGHT LOBE: 1.51 ± 0.44; left lobe: 1.57 ± 0.40) than in controls (right lobe: 1.08 ± 0.10; left lobe: 1.12 ± 0.13) (right lobe: P = 0.002; left lobe: P = 0.013). We found no significant correlation between right and left lobe SWVs in cases (P = 0.779) or controls (P = 0.385). The SWV cut-off that best distinguished cases from controls was 1.25 m/sec (accuracy: AUC=0.885; sensitivity: 70.6%; specificity: 95.5%). CONCLUSIONS: ARFI elastography is a noninvasive ultrasonographic technique that can differentiate healthy subjects from patients with fibrotic stages of chronic liver disease.

SUBMITTER: Righi S 

PROVIDER: S-EPMC3558243 | biostudies-literature | 2012 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

ARFI elastography in patients with chronic autoimmune liver diseases: A preliminary study.

Righi S S   Fiorini E E   De Molo C C   Cipriano V V   Cassani F F   Muratori L L   Lenzi M M   Morselli Labate A M AM   Serra C C  

Journal of ultrasound 20121025 4


<h4>Objective</h4>Acoustic radiation force impulse (ARFI) is a new software-based technique that evaluates liver stiffness during B-mode ultrasonography. The purpose of this study was to evaluate the accuracy of ARFI in distinguishing patients with chronic autoimmune liver disease from healthy subjects.<h4>Material and methods</h4>We enrolled 9 adult patients (8 women, 1 man; age 48.1 ± 12.8 years) with chronic autoimmune disease (primary biliary cirrhosis (PBC, n = 3), autoimmune hepatitis (AIH  ...[more]

Similar Datasets

| S-EPMC6532896 | biostudies-literature
| S-EPMC3558087 | biostudies-literature
| S-EPMC5703509 | biostudies-literature
| S-EPMC9564189 | biostudies-literature
| S-EPMC4535884 | biostudies-literature
| S-EPMC4631322 | biostudies-literature
| S-EPMC3995722 | biostudies-literature
| S-EPMC4449891 | biostudies-literature
| S-EPMC11335937 | biostudies-literature
| S-EPMC5493583 | biostudies-other