Unknown

Dataset Information

0

Interferon gamma release assays for the diagnosis of latent TB infection in HIV-infected individuals in a low TB burden country.


ABSTRACT:

Background

Interferon gamma release assays (IGRAs) are used to diagnose latent tuberculosis infection. Two IGRAs are commercially available: the Quantiferon TB Gold In Tube (QFT-IT) and the T-SPOT.TB. There is debate as to which test to use in HIV+ individuals. Previous publications from high TB burden countries have raised concerns that the sensitivity of the QFT-IT assay, but not the T-SPOT.TB, may be impaired in HIV+ individuals with low CD4+ T-cell counts. We sought to compare the tests in a low TB burden setting.

Methodology/principal findings

T-SPOT.TB, QFT-IT, and tuberculin skin tests (TST) were performed in HIV infected individuals. Results were related to patient characteristics. McNemar's test, multivariate regression and correlation analysis were carried out using SPSS (SPSS Inc). 256 HIV infected patients were enrolled in the study. The median CD4+ T-cell count was 338 cells/µL (range 1-1328). 37 (14%) patients had a CD4+ T-cell count of <100 cells/µL. 46/256 (18% ) of QFT-IT results and 28/256 (11%) of T-SPOT.TB results were positive. 6 (2%) of QFT-IT and 18 (7%) of T-SPOT.TB results were indeterminate. An additional 9 (4%) of T-SPOT.TB results were unavailable as tests were not performed due to insufficient cells or clotting of the sample. We found a statistically significant association between lower CD4+ T-cell count and negative QFT-IT results (OR 1.055, p=0.03), and indeterminate/unavailable T-SPOT.TB results (OR 1.079, p=0.02).

Conclusions/significance

In low TB prevalence settings, the QFT-IT yields more positive and fewer indeterminate results than T-SPOT.TB. Negative results on the QFT-IT and indeterminate/unavailable results on the T-SPOT.TB were more common in individuals with low CD4+ T-cell counts.

SUBMITTER: Cheallaigh CN 

PROVIDER: S-EPMC3559731 | biostudies-literature | 2013

REPOSITORIES: biostudies-literature

altmetric image

Publications

Interferon gamma release assays for the diagnosis of latent TB infection in HIV-infected individuals in a low TB burden country.

Cheallaigh Clíona Ní CN   Fitzgerald Ian I   Grace Jacinta J   Singh Gurmit Jagjit GJ   El-Eraki Nahla N   Gibbons Noel N   Keane Joseph J   Rogers Thomas R TR   Clarke Susan S   Bergin Colm C  

PloS one 20130130 1


<h4>Background</h4>Interferon gamma release assays (IGRAs) are used to diagnose latent tuberculosis infection. Two IGRAs are commercially available: the Quantiferon TB Gold In Tube (QFT-IT) and the T-SPOT.TB. There is debate as to which test to use in HIV+ individuals. Previous publications from high TB burden countries have raised concerns that the sensitivity of the QFT-IT assay, but not the T-SPOT.TB, may be impaired in HIV+ individuals with low CD4+ T-cell counts. We sought to compare the te  ...[more]

Similar Datasets

| S-EPMC3383328 | biostudies-literature
| S-EPMC5388595 | biostudies-literature
| S-EPMC4107858 | biostudies-other
| S-EPMC5070182 | biostudies-literature
| S-EPMC5517191 | biostudies-other
| S-EPMC4339676 | biostudies-literature
| S-EPMC9301964 | biostudies-literature
| S-EPMC5705142 | biostudies-literature
| S-EPMC3910908 | biostudies-other
| S-EPMC4858200 | biostudies-literature