Unknown

Dataset Information

0

Coronary aspirate TNF? reflects saphenous vein bypass graft restenosis risk in diabetic patients.


ABSTRACT: Patients with diabetes mellitus (DM) have an increased risk for periprocedural complications and adverse cardiac events after percutaneous coronary intervention. We addressed the potential for coronary microvascular obstruction and restenosis in patients with and without DM undergoing stenting for saphenous vein bypass graft (SVG) stenosis under protection with a distal occlusion/aspiration device.SVG plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Percent diameter stenosis was determined from quantitative coronary angiography before, immediately after and 6?months after stent implantation. Coronary aspirate was retrieved during stent implantation and divided into particulate debris and plasma. Total calcium, several vasoconstrictors, and tumor necrosis factor (TNF)? in particulate debris and coronary aspirate plasma were determined.Patients with and without DM had similar plaque volume, but larger necrotic core and greater particulate debris release in patients with than without DM (20.3±2.7 vs. 12.7±2.6% and 143.9±19.3 vs. 75.1±10.4?mg, P<0.05). The TNF? concentration in particulate debris and coronary aspirate plasma was higher in patients with than without DM (15.9±6.6 vs. 5.1±2.4 pmol/mg and 2.2±0.7 vs. 1.1±0.2 pmol/L, P<0.05), whereas total calcium and vasoconstrictors were not different. Patients with DM had a greater percent diameter stenosis 6?months after stent implantation than those without DM (22.17±5.22 vs. 6.34±1.11%, P<0.05). The increase in TNF? immediately after stent implantation correlated with restenosis 6?months later (r=0.69, P<0.05).In diabetics, particulate debris and coronary aspirate plasma contained more TNF?, which might reflect the activity of the underlying atherosclerotic process.URL: http://www.clinicaltrials.gov/ct2/results?term=NCT01430884; unique identifier: NCT01430884.

SUBMITTER: Baars T 

PROVIDER: S-EPMC3560373 | biostudies-literature | 2013 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Coronary aspirate TNFα reflects saphenous vein bypass graft restenosis risk in diabetic patients.

Baars Theodor T   Konorza Thomas T   Kahlert Philipp P   Möhlenkamp Stefan S   Erbel Raimund R   Heusch Gerd G   Kleinbongard Petra P  

Cardiovascular diabetology 20130110


<h4>Background</h4>Patients with diabetes mellitus (DM) have an increased risk for periprocedural complications and adverse cardiac events after percutaneous coronary intervention. We addressed the potential for coronary microvascular obstruction and restenosis in patients with and without DM undergoing stenting for saphenous vein bypass graft (SVG) stenosis under protection with a distal occlusion/aspiration device.<h4>Methods</h4>SVG plaque volume and composition were analyzed using intravascu  ...[more]

Similar Datasets

| S-EPMC10081881 | biostudies-literature
| S-EPMC10902658 | biostudies-literature
| S-EPMC3653490 | biostudies-literature
| S-EPMC4206593 | biostudies-literature
| S-EPMC5660200 | biostudies-literature
| S-EPMC5493189 | biostudies-other
| S-EPMC3004149 | biostudies-literature
| S-EPMC8387700 | biostudies-literature
| S-EPMC3407956 | biostudies-literature
| S-EPMC7089755 | biostudies-literature