Measurement of variceal pressure with a computerized endoscopic manometry: validation and effect of propranolol therapy in cirrhotic patients.


ABSTRACT:

Background and purpose

Recently, we invented a computerized endoscopic balloon manometry (CEBM) to measure variceal pressure (VP) in cirrhotic patient. The purpose of this study was to evaluate the reliability and feasibility of this method, and whether this technique provided further information to pharmacological therapy.

Patients and methods

VP measurements were performed in 83 cirrhotic patients and compared with HVPG as well as endoscopic bleeding risk parameters. Furthermore, VP was assessed before and during propranolol therapy in 30 patients without previous bleeding.

Results

VP measurements were successful in 96% (83/86) of all patients. Of the 83 patients, the VP correlated closely with the HVPG (P<0.001). The presence of red colour signs and the size of varices were strongly associated with VP. Patients with previous bleeding had higher VP than those who had not yet experienced bleeding. In univariate analysis, the level of VP, the size of varices, and red color signs predicted a higher risk of bleeding. The multiple logistic regression model revealed that VP was the major risk factor for bleeding. In 30 patients receiving propranolol, VP significantly decreased from 21.1 ± 3.5 mmHg before therapy to 18.1 ± 3.3 mmHg after 3 months and to 16.3 ± 4.0 mmHg after 6 months. Comparing the mean decrease in VP with that in hepatic venous pressure gradient (HVPG), the decrease in VP was more obvious than HVPG response to propranolol.

Conclusions

This study showed that CEBM is safe and practical to assess VP in cirrhotic patient. It has the potential to be used as a clinical method to assess the risk of variceal bleeding and the effects of pharmacological therapy.

Trial registration

Effect of vasoactive drugs on esophageal variceal hemodynamics in patients with portal hypertension. Chinese Clinical Trial Registry -TRC-08000252.

SUBMITTER: Kong DR 

PROVIDER: S-EPMC3576342 | biostudies-literature | 2013

REPOSITORIES: biostudies-literature

altmetric image

Publications

Measurement of variceal pressure with a computerized endoscopic manometry: validation and effect of propranolol therapy in cirrhotic patients.

Kong De-Run DR   Zhang Chao C   Zhang Lei L   Wang Jing-Guang JG   Xiong Zhuang Z   Li Pan P   Xu Jian-Ming JM  

PloS one 20130219 2


<h4>Background and purpose</h4>Recently, we invented a computerized endoscopic balloon manometry (CEBM) to measure variceal pressure (VP) in cirrhotic patient. The purpose of this study was to evaluate the reliability and feasibility of this method, and whether this technique provided further information to pharmacological therapy.<h4>Patients and methods</h4>VP measurements were performed in 83 cirrhotic patients and compared with HVPG as well as endoscopic bleeding risk parameters. Furthermore  ...[more]

Similar Datasets

| S-EPMC7004788 | biostudies-literature
| S-EPMC6811355 | biostudies-literature
| S-EPMC7276934 | biostudies-literature
| S-EPMC8171152 | biostudies-literature
| S-EPMC1727391 | biostudies-other
| S-EPMC8011774 | biostudies-literature
| S-EPMC9175143 | biostudies-literature
| S-EPMC9317208 | biostudies-literature
| S-EPMC8599938 | biostudies-literature
| S-EPMC4680175 | biostudies-other