Self-gated CINE MRI for combined contrast-enhanced imaging and wall-stiffness measurements of murine aortic atherosclerotic lesions.


ABSTRACT:

Background

High-resolution contrast-enhanced imaging of the murine atherosclerotic vessel wall is difficult due to unpredictable flow artifacts, motion of the thin artery wall and problems with flow suppression in the presence of a circulating contrast agent.

Methods and results

We applied a 2D-FLASH retrospective-gated CINE MRI method at 9.4T to characterize atherosclerotic plaques and vessel wall distensibility in the aortic arch of aged ApoE(-/-) mice after injection of a contrast agent. The method enabled detection of contrast enhancement in atherosclerotic plaques in the aortic arch after I.V. injection of micelles and iron oxides resulting in reproducible plaque enhancement. Both contrast agents were taken up in the plaque, which was confirmed by histology. Additionally, the retrospective-gated CINE method provided images of the aortic wall throughout the cardiac cycle, from which the vessel wall distensibility could be calculated. Reduction in plaque size by statin treatment resulted in lower contrast enhancement and reduced wall stiffness.

Conclusions

The retrospective-gated CINE MRI provides a robust and simple way to detect and quantify contrast enhancement in atherosclerotic plaques in the aortic wall of ApoE(-/-) mice. From the same scan, plaque-related changes in stiffness of the aortic wall can be determined. In this mouse model, a correlation between vessel wall stiffness and atherosclerotic lesions was found.

SUBMITTER: den Adel B 

PROVIDER: S-EPMC3589480 | biostudies-literature | 2013

REPOSITORIES: biostudies-literature

altmetric image

Publications

Self-gated CINE MRI for combined contrast-enhanced imaging and wall-stiffness measurements of murine aortic atherosclerotic lesions.

den Adel Brigit B   van der Graaf Linda M LM   Strijkers Gustav J GJ   Lamb Hildo J HJ   Poelmann Robert E RE   van der Weerd Louise L  

PloS one 20130305 3


<h4>Background</h4>High-resolution contrast-enhanced imaging of the murine atherosclerotic vessel wall is difficult due to unpredictable flow artifacts, motion of the thin artery wall and problems with flow suppression in the presence of a circulating contrast agent.<h4>Methods and results</h4>We applied a 2D-FLASH retrospective-gated CINE MRI method at 9.4T to characterize atherosclerotic plaques and vessel wall distensibility in the aortic arch of aged ApoE(-/-) mice after injection of a contr  ...[more]

Similar Datasets

| S-EPMC4274255 | biostudies-literature
| S-EPMC5036833 | biostudies-literature
| S-EPMC10253575 | biostudies-literature
| S-EPMC2946451 | biostudies-literature
| S-EPMC5831265 | biostudies-literature
| S-EPMC7236008 | biostudies-literature
| S-EPMC8321019 | biostudies-literature
| S-EPMC7773673 | biostudies-literature
| S-EPMC7978027 | biostudies-literature
| S-EPMC7381445 | biostudies-literature