Unknown

Dataset Information

0

A microfluidic electrochemiluminescent device for detecting cancer biomarker proteins.


ABSTRACT: We describe an electrochemiluminescence (ECL) immunoarray incorporated into a prototype microfluidic device for highly sensitive protein detection and apply this system to accurate, sensitive measurements of prostate-specific antigen (PSA) and interleukin-6 (IL-6) in serum. The microfluidic system employed three molded polydimethylsiloxane (PDMS) channels on a conductive pyrolytic graphite chip (2.5 × 2.5 cm) inserted into a machined chamber and interfaced with a pump, switching valve, and sample injector. Each of the three PDMS channels encompasses three 3 ?L analytical wells. Capture-antibody-decorated single-wall carbon nanotube forests are fabricated in the bottom of the wells. The antigen is captured by these antibodies on the well bottoms. Then, a RuBPY-silica-secondary antibody (Ab2) label is injected to bind to antigen on the array, followed by injection of sacrificial reductant tripropylamine (TPrA) to produce ECL. For detection, the chip is placed into an open-top ECL measuring cell, and the channels are in contact with electrolyte in the chamber. Potential applied at 0.95 V versus Ag/AgCl oxidizes TPrA to produce ECL by redox cycling the RuBPY species in the particles, and ECL light is measured by a charge-coupled device camera. This approach achieved ultralow detection limits of 100 fg mL(-1) for PSA (9 zeptomole) and 10 fg mL(-1) (1 zeptomole) for IL-6 in calf serum, a 10-25-fold improvement of a similar non-microfluidic array. PSA and IL-6 in synthetic cancer patient serum samples were detected in 1.1 h and results correlated well with single-protein enzyme-linked immunosorbent assays.

SUBMITTER: Sardesai NP 

PROVIDER: S-EPMC3610849 | biostudies-literature | 2013 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

A microfluidic electrochemiluminescent device for detecting cancer biomarker proteins.

Sardesai Naimish P NP   Kadimisetty Karteek K   Faria Ronaldo R   Rusling James F JF  

Analytical and bioanalytical chemistry 20130111 11


We describe an electrochemiluminescence (ECL) immunoarray incorporated into a prototype microfluidic device for highly sensitive protein detection and apply this system to accurate, sensitive measurements of prostate-specific antigen (PSA) and interleukin-6 (IL-6) in serum. The microfluidic system employed three molded polydimethylsiloxane (PDMS) channels on a conductive pyrolytic graphite chip (2.5 × 2.5 cm) inserted into a machined chamber and interfaced with a pump, switching valve, and sampl  ...[more]

Similar Datasets

| S-EPMC3169383 | biostudies-literature
2015-07-21 | GSE65516 | GEO
| S-EPMC5034346 | biostudies-literature
2019-02-25 | GSE119271 | GEO
2019-12-22 | GSE128720 | GEO
2024-02-24 | GSE256086 | GEO