Ontology highlight
ABSTRACT: Objective
The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT.Design
The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample FIT screening. The FIT cut-off level varied between 50 and 200 ng haemoglobin/ml, and the screening schedule was varied with respect to age range and interval. In addition, different definitions for positivity of the two-sample FIT were considered: at least one positive sample, two positive samples, or the mean of both samples being positive.Results
Within an exemplary screening strategy, biennial FIT from the age of 55-75 years, one-sample FIT provided 76.0-97.0 life-years gained (LYG) per 1000 individuals, at a cost of € 259,000-264,000 (range reflects different FIT cut-off levels). Two-sample FIT screening with at least one sample being positive provided 7.3-12.4 additional LYG compared with one-sample FIT at an extra cost of € 50,000-59,000. However, when all screening intervals and age ranges were considered, intensifying screening with one-sample FIT provided equal or more LYG at lower costs compared with two-sample FIT.Conclusion
If attendance to screening does not differ between strategies it is recommended to increase the number of screening rounds with one-sample FIT screening, before considering increasing the number of FIT samples provided per screening round.
SUBMITTER: Goede SL
PROVIDER: S-EPMC3618685 | biostudies-literature | 2013 May
REPOSITORIES: biostudies-literature
Goede S Lucas SL van Roon Aafke H C AH Reijerink Jacqueline C I Y JC van Vuuren Anneke J AJ Lansdorp-Vogelaar Iris I Habbema J Dik F JD Kuipers Ernst J EJ van Leerdam Monique E ME van Ballegooijen Marjolein M
Gut 20120405 5
<h4>Objective</h4>The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT.<h4>Design</h4>The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample F ...[more]