Unknown

Dataset Information

0

Wafer-scale mitochondrial membrane potential assays.


ABSTRACT: It has been reported that mitochondrial metabolic and biophysical parameters are associated with degenerative diseases and the aging process. To evaluate these biochemical parameters, current technology requires several hundred milligrams of isolated mitochondria for functional assays. Here, we demonstrate manufacturable wafer-scale mitochondrial functional assay lab-on-a-chip devices, which require mitochondrial protein quantities three orders of magnitude less than current assays, integrated onto 4'' standard silicon wafer with new fabrication processes and materials. Membrane potential changes of isolated mitochondria from various well-established cell lines such as human HeLa cell line (Heb7A), human osteosarcoma cell line (143b) and mouse skeletal muscle tissue were investigated and compared. This second generation integrated lab-on-a-chip system developed here shows enhanced structural durability and reproducibility while increasing the sensitivity to changes in mitochondrial membrane potential by an order of magnitude as compared to first generation technologies. We envision this system to be a great candidate to substitute current mitochondrial assay systems.

SUBMITTER: Lim TS 

PROVIDER: S-EPMC3658830 | biostudies-literature | 2012 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Wafer-scale mitochondrial membrane potential assays.

Lim Tae-Sun TS   Davila Antonio A   Zand Katayoun K   Wallace Douglas C DC   Burke Peter J PJ  

Lab on a chip 20120525 15


It has been reported that mitochondrial metabolic and biophysical parameters are associated with degenerative diseases and the aging process. To evaluate these biochemical parameters, current technology requires several hundred milligrams of isolated mitochondria for functional assays. Here, we demonstrate manufacturable wafer-scale mitochondrial functional assay lab-on-a-chip devices, which require mitochondrial protein quantities three orders of magnitude less than current assays, integrated o  ...[more]

Similar Datasets

| S-EPMC8654297 | biostudies-literature
| S-EPMC8516594 | biostudies-literature
| S-EPMC3931460 | biostudies-literature
| S-EPMC8620583 | biostudies-literature
| S-EPMC8689146 | biostudies-literature
2020-11-27 | GSE162197 | GEO
2015-12-23 | GSE74001 | GEO
| S-EPMC5996022 | biostudies-literature
| S-EPMC5789397 | biostudies-literature
| S-EPMC8442871 | biostudies-literature