Concentric and eccentric time-under-tension during strengthening exercises: validity and reliability of stretch-sensor recordings from an elastic exercise-band.


ABSTRACT:

Background

Total, single repetition and contraction-phase specific (concentric and eccentric) time-under-tension (TUT) are important exercise-descriptors, as they are linked to the physiological and clinical response in exercise and rehabilitation.

Objective

To investigate the validity and reliability of total, single repetition, and contraction-phase specific TUT during shoulder abduction exercises, based on data from a stretch-sensor attached to an elastic exercise band.

Methods

A concurrent validity and interrater reliability study with two raters was conducted. Twelve participants performed five sets of 10 repetitions of shoulder abduction exercises with an elastic exercise band. Exercises were video-recorded to assess concurrent validity between TUT from stretch-sensor data and from video recordings (gold standard). Agreement between methods was calculated using Limits of Agreement (LoA), and the association was assessed by Pearson correlation coefficients. Interrater reliability was calculated using intraclass correlation coefficients (ICC 2.1).

Results

Total, single repetition, and contraction-phase specific TUT - determined from video and stretch-sensor data - were highly correlated (r>0.99). Agreement between methods was high, as LoA ranged from 0.0 to 3.1 seconds for total TUT (2.6% of mean TUT), from -0.26 to 0.56 seconds for single repetition TUT (6.9%), and from -0.29 to 0.56 seconds for contraction-phase specific TUT (13.2-21.1%). Interrater reliability for total, single repetition and contraction-phase specific TUT was high (ICC>0.99). Interrater agreement was high, as LoA ranged from -2.11 to 2.56 seconds for total TUT (4.7%), from -0.46 to 0.50 seconds for single repetition TUT (9.7%) and from -0.41 to 0.44 seconds for contraction-phase specific TUT (5.2-14.5%).

Conclusion

Data from a stretch-sensor attached to an elastic exercise band is a valid measure of total and single repetition time-under-tension, and the procedure is highly reliable. This method will enable clinicians and researchers to objectively quantify if home-based exercises are performed as prescribed, with respect to time-under-tension.

SUBMITTER: Skovdal Rathleff M 

PROVIDER: S-EPMC3692465 | biostudies-literature | 2013

REPOSITORIES: biostudies-literature

altmetric image

Publications

Concentric and eccentric time-under-tension during strengthening exercises: validity and reliability of stretch-sensor recordings from an elastic exercise-band.

Skovdal Rathleff Michael M   Thorborg Kristian K   Bandholm Thomas T  

PloS one 20130625 6


<h4>Background</h4>Total, single repetition and contraction-phase specific (concentric and eccentric) time-under-tension (TUT) are important exercise-descriptors, as they are linked to the physiological and clinical response in exercise and rehabilitation.<h4>Objective</h4>To investigate the validity and reliability of total, single repetition, and contraction-phase specific TUT during shoulder abduction exercises, based on data from a stretch-sensor attached to an elastic exercise band.<h4>Meth  ...[more]

Similar Datasets

| S-EPMC10020054 | biostudies-literature
| S-EPMC6746593 | biostudies-literature
| S-EPMC8419330 | biostudies-literature
| S-EPMC7451834 | biostudies-literature
| S-EPMC8966379 | biostudies-literature
| S-EPMC6176742 | biostudies-literature
| S-EPMC5278235 | biostudies-literature
| S-EPMC8671437 | biostudies-literature
| S-EPMC5684744 | biostudies-literature