Clinical measurement of von Willebrand factor by fluorescence correlation spectroscopy.


ABSTRACT: BACKGROUND:Identification of von Willebrand factor (vWF) abnormalities in a variety of conditions is hampered by the limitations of currently available diagnostic tests. Although direct multimer visualization by immunoelectrophoresis is a commonly used method, it is impractical as a routine clinical test. In this study, we used a biophysical analysis tool, fluorescence correlation spectroscopy (FCS), to measure vWF distributions. The goals were to develop a method that is quicker and simpler than vWF gel electrophoresis and to evaluate the potential of FCS as a clinical diagnostic technique. METHODS:We analyzed plasma from 12 patients with type 1 von Willebrand disease (vWD), 14 patients with type 2 vWD, and 10 healthy controls using a fluctuation-based immunoassay approach. RESULTS:FCS enabled identification and proper classification of type 1 and type 2 vWD, producing quantitative results that correspond to qualitative gel multimer patterns. FCS required minimal sample preparation and only a 5-min analysis time. CONCLUSIONS:This study represents the first implementation of FCS for clinical diagnostics directly on human plasma. The technique shows potential for further vWF studies and as a generally applicable laboratory test method.

SUBMITTER: Torres R 

PROVIDER: S-EPMC3733381 | biostudies-literature | 2012 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Clinical measurement of von Willebrand factor by fluorescence correlation spectroscopy.

Torres Richard R   Genzen Jonathan R JR   Levene Michael J MJ  

Clinical chemistry 20120326 6


<h4>Background</h4>Identification of von Willebrand factor (vWF) abnormalities in a variety of conditions is hampered by the limitations of currently available diagnostic tests. Although direct multimer visualization by immunoelectrophoresis is a commonly used method, it is impractical as a routine clinical test. In this study, we used a biophysical analysis tool, fluorescence correlation spectroscopy (FCS), to measure vWF distributions. The goals were to develop a method that is quicker and sim  ...[more]

Similar Datasets

| S-EPMC8351889 | biostudies-literature
| S-EPMC7948283 | biostudies-literature
| S-EPMC3856360 | biostudies-literature
| S-EPMC3129199 | biostudies-literature
| S-EPMC7443431 | biostudies-literature
| S-EPMC6524857 | biostudies-literature
2010-11-10 | GSE19816 | GEO
| S-EPMC6232194 | biostudies-literature
| S-EPMC4284388 | biostudies-literature
| S-EPMC4824554 | biostudies-literature