Unknown

Dataset Information

0

Ocular decompression with cotton swabs lowers intraocular pressure elevation after intravitreal injection.


ABSTRACT: To determine the effect of preinjection ocular decompression by cotton swabs on the immediate rise in intraocular pressure (IOP) after intravitreal injections.Forty-eight patients receiving 0.05 mL ranibizumab injections in a retina clinic were randomized to 2 anesthetic methods in each eye on the same day (if bilateral disease) or on consecutive visits (if unilateral disease). One method utilized cotton swabs soaked in 4% lidocaine applied to the globe with moderate pressure and the other 3.5% lidocaine gel applied without pressure. IOPs were recorded at baseline (before injection) and at 0, 5, 10, and 15 minutes after the injection until the IOP was ?30 mm Hg. The IOP elevations from baseline were compared after the 2 anesthetic methods.The preinjection mean IOP (SD, mm Hg) was 15.5 (3.3) before the cotton swabs and 15.9 (3.0) before the gel (P=0.28). Mean IOP (SD, mm Hg) change immediately after injection was 25.7 (9.2) after the cotton swabs and 30.9 (9.9) after the gel (P=0.001). Thirty-five percent of gel eyes had IOP?50 mm Hg compared with only 10% of cotton swab eyes immediately after the injection (P<0.001).Decompressing the eye with cotton swabs during anesthetic preparation before an intravitreal injection produces a significantly lower IOP spike after the injection.

SUBMITTER: Gregori NZ 

PROVIDER: S-EPMC3769433 | biostudies-literature | 2014 Oct-Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ocular decompression with cotton swabs lowers intraocular pressure elevation after intravitreal injection.

Gregori Ninel Z NZ   Weiss Matthew J MJ   Goldhardt Raquel R   Schiffman Joyce C JC   Vega Edgardo E   Mattis Cherrie-Ann CA   Shi Wei W   Kelley Linda L   Hernandez Vilma V   Feuer William J WJ  

Journal of glaucoma 20141001 8


<h4>Objective</h4>To determine the effect of preinjection ocular decompression by cotton swabs on the immediate rise in intraocular pressure (IOP) after intravitreal injections.<h4>Methods</h4>Forty-eight patients receiving 0.05 mL ranibizumab injections in a retina clinic were randomized to 2 anesthetic methods in each eye on the same day (if bilateral disease) or on consecutive visits (if unilateral disease). One method utilized cotton swabs soaked in 4% lidocaine applied to the globe with mod  ...[more]

Similar Datasets

| S-EPMC4909679 | biostudies-literature
| S-EPMC6894825 | biostudies-literature
2013-05-17 | E-GEOD-40009 | biostudies-arrayexpress
| S-EPMC3281054 | biostudies-literature
2013-05-17 | GSE40009 | GEO
| S-EPMC7396190 | biostudies-literature
| S-EPMC5175276 | biostudies-literature
| S-EPMC7997020 | biostudies-literature
| S-EPMC4035318 | biostudies-literature
| S-EPMC7571289 | biostudies-literature