Health risk assessment of inhalation exposure to formaldehyde and benzene in newly remodeled buildings, Beijing.


ABSTRACT:

Objective

To assess health risks associated with inhalation exposure to formaldehyde and benzene mainly emitted from building and decoration materials in newly remodeled indoor spaces in Beijing.

Methods

We tested the formaldehyde and benzene concentrations in indoor air of 410 dwellings and 451 offices remodeled within the past year, in which the occupants had health concerns about indoor air quality. To assess non-carcinogenic health risks, we compared the data to the health guidelines in China and USA, respectively. To assess carcinogenic health risks, we first modeled indoor personal exposure to formaldehyde and benzene using the concentration data, and then estimated the associated cancer risks by multiplying the indoor personal exposure by the Inhalation Unit Risk values (IURs) provided by the U.S. EPA Integrated Risk Information System (U.S. EPA IRIS) and the California Office of Environmental Health Hazard Assessment (OEHHA), respectively.

Results

(1) The indoor formaldehyde concentrations of 85% dwellings and 67% offices were above the acute Reference Exposure Level (REL) recommended by the OEHHA and the concentrations of all tested buildings were above the chronic REL recommended by the OEHHA; (2) The indoor benzene concentrations of 12% dwellings and 32% offices exceeded the reference concentration (RfC) recommended by the U.S. EPA IRIS; (3) The median cancer risks from indoor exposure to formaldehyde and benzene were 1,150 and 106 per million (based on U.S. EPA IRIS IURs), 531 and 394 per million (based on OEHHA IURs).

Conclusions

In the tested buildings, formaldehyde exposure may pose acute and chronic non-carcinogenic health risks to the occupants, whereas benzene exposure may pose chronic non-carcinogenic risks to the occupants. Exposure to both compounds is associated with significant carcinogenic risks. Improvement in ventilation, establishment of volatile organic compounds (VOCs) emission labeling systems for decorating and refurbishing materials are recommended to reduce indoor VOCs exposure.

SUBMITTER: Huang L 

PROVIDER: S-EPMC3828412 | biostudies-literature | 2013

REPOSITORIES: biostudies-literature

Similar Datasets

2012-09-01 | E-GEOD-34978 | biostudies-arrayexpress
| S-EPMC9665125 | biostudies-literature
| S-EPMC8979994 | biostudies-literature
| S-EPMC4053885 | biostudies-other
| S-EPMC3273041 | biostudies-literature
2011-05-04 | GSE27263 | GEO
| S-EPMC8011796 | biostudies-literature
| S-EPMC7825799 | biostudies-literature
| S-EPMC7433412 | biostudies-literature
| S-EPMC4299857 | biostudies-literature