Unknown

Dataset Information

0

Voltammetric microwell array for oxidized guanosine in intact ds-DNA.


ABSTRACT: Oxidative stress in humans causes damage to biomolecules by generating reactive oxygen species (ROS). DNA can be oxidatively damaged by ROS, which may lead to carcinogenesis. Here we report a microfluidic electrochemical array designed to rapidly detect oxidation in intact DNA in replicate measurements. Sensor arrays were fabricated by wet-chemistry patterning of gold compact discs. The eight-sensor array is incorporated into a 60 ?L microfluidic channel connected to a pump and sample valve. The array features 7 nm thick osmium bipyridyl poly(vinylpyridine) chloride [Os(bpy)2(PVP)10Cl](+) films assembled layer-by-layer with polyions onto the gold sensors. 8-Hydroxy-7,8-hydro-2'-deoxyguanosine (8-oxodG) is selectively oxidized by [Os(bpy)2(PVP)10Cl](+) in intact ds-DNA to provide catalytic square wave voltammograms (SWV). The device is easy-to-use, fast, inexpensive, reusable, and can detect one 8-oxodG per 6600 nucleobases. The mass detection limit is 150-fold lower than a previously reported dip-and-read voltammetric sensor for oxidized DNA. Fast assays (<1 min) and moderate sample consumption (15 pmol DNA) suggest potential for research and clinical applications. Practical use is illustrated by detecting DNA oxidation from cigarette smoke and ash extracts in dispersions with NADPH and Cu(2+).

SUBMITTER: Song B 

PROVIDER: S-EPMC3856883 | biostudies-literature | 2013 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Voltammetric microwell array for oxidized guanosine in intact ds-DNA.

Song Boya B   Pan Shenmin S   Tang Chi C   Li Dandan D   Rusling James F JF  

Analytical chemistry 20131028 22


Oxidative stress in humans causes damage to biomolecules by generating reactive oxygen species (ROS). DNA can be oxidatively damaged by ROS, which may lead to carcinogenesis. Here we report a microfluidic electrochemical array designed to rapidly detect oxidation in intact DNA in replicate measurements. Sensor arrays were fabricated by wet-chemistry patterning of gold compact discs. The eight-sensor array is incorporated into a 60 μL microfluidic channel connected to a pump and sample valve. The  ...[more]

Similar Datasets

| S-EPMC8343185 | biostudies-literature
| S-EPMC3249509 | biostudies-literature
| S-EPMC8227627 | biostudies-literature
| S-EPMC3169383 | biostudies-literature
| S-EPMC3135426 | biostudies-literature
| S-EPMC4560352 | biostudies-literature
| S-EPMC5177905 | biostudies-other
| S-EPMC6187582 | biostudies-literature
| S-EPMC7754331 | biostudies-literature
| S-EPMC6170868 | biostudies-literature