Unknown

Dataset Information

0

Nucleic acid sample preparation using spontaneous biphasic plug flow.


ABSTRACT: Nucleic acid (NA) extraction and purification has become a common technique in both research and clinical laboratories. Current methods require repetitive wash steps with a pipet that are laborious and time-consuming, making the procedure inefficient for clinical settings. We present here a simple technique that relies on spontaneous biphasic plug flow inside a capillary to achieve sample preparation. By filling the sample with oil, aqueous contaminants were displaced from the captured NA without pipetting wash buffers or use of external force and equipment. mRNA from mammalian cell culture was purified, and polymerase chain reaction (PCR) amplification showed similar threshold cycle values as those obtained from a commercially available kit. Human immunodeficiency virus (HIV) viral-like particles were spiked into serum and a 5-fold increase in viral RNA extraction yield was achieved compared to the conventional wash method. In addition, viral RNA was successfully purified from human whole blood, and a limit of detection of approximately 14 copies of RNA extracted per sample was determined. The results demonstrate the utility of the current technique for nucleic acid purification for clinical purposes, and the overall approach provides a potential method to implement nucleic acid testing in low-resource settings.

SUBMITTER: Thomas PC 

PROVIDER: S-EPMC3858960 | biostudies-literature | 2013 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Nucleic acid sample preparation using spontaneous biphasic plug flow.

Thomas Peter C PC   Strotman Lindsay N LN   Theberge Ashleigh B AB   Berthier Erwin E   O'Connell Rachel R   Loeb Jennifer M JM   Berry Scott M SM   Beebe David J DJ  

Analytical chemistry 20130904 18


Nucleic acid (NA) extraction and purification has become a common technique in both research and clinical laboratories. Current methods require repetitive wash steps with a pipet that are laborious and time-consuming, making the procedure inefficient for clinical settings. We present here a simple technique that relies on spontaneous biphasic plug flow inside a capillary to achieve sample preparation. By filling the sample with oil, aqueous contaminants were displaced from the captured NA withou  ...[more]

Similar Datasets

| S-EPMC8115986 | biostudies-literature
| S-EPMC3085533 | biostudies-other
| S-EPMC8565614 | biostudies-literature
| S-EPMC7382727 | biostudies-literature
| S-EPMC8433180 | biostudies-literature
| S-EPMC5431006 | biostudies-literature
| S-EPMC4109970 | biostudies-literature
| S-EPMC9930993 | biostudies-literature
2023-11-02 | GSE246516 | GEO
| S-EPMC9758654 | biostudies-literature