Microcomputed tomography provides high accuracy congenital heart disease diagnosis in neonatal and fetal mice.


ABSTRACT: Mice are well suited for modeling human congenital heart disease (CHD), given their 4-chamber cardiac anatomy. However, mice with CHD invariably die prenatally/neonatally, causing CHD phenotypes to be missed. Therefore, we investigated the efficacy of noninvasive microcomputed tomography (micro-CT) to screen for CHD in stillborn/fetal mice. These studies were performed using chemically mutagenized mice expected to be enriched for birth defects, including CHD.Stillborn/fetal mice obtained from the breeding of N-ethyl-N-nitrosourea mutagenized mice were formalin-fixed and stained with iodine, then micro-CT scanned. Those diagnosed with CHD and some CHD-negative pups were necropsied. A subset of these were further analyzed by histopathology to confirm the CHD/no-CHD diagnosis. Micro-CT scanning of 2105 fetal/newborn mice revealed an abundance of ventricular septal defects (n=307). Overall, we observed an accuracy of 89.8% for ventricular septal defect diagnosis. Outflow tract anomalies identified by micro-CT included double outlet right ventricle (n=36), transposition of the great arteries (n=14), and persistent truncus arteriosus (n=3). These were diagnosed with a 97.4% accuracy. Aortic arch anomalies also were readily detected with an overall 99.6% accuracy. This included right aortic arch (n=28) and coarctation/interrupted aortic arch (n=12). Also detected by micro-CT were atrioventricular septal defects (n=22), tricuspid hypoplasia/atresia (n=13), and coronary artery fistulas (n=16). They yielded accuracies of 98.9%, 100%, and 97.8%, respectively.Contrast enhanced micro-CT imaging in neonatal/fetal mice can reliably detect a wide spectrum of CHD. We conclude that micro-CT imaging can be used for routine rapid assessments of structural heart defects in fetal/newborn mice.

SUBMITTER: Kim AJ 

PROVIDER: S-EPMC3908688 | biostudies-literature | 2013 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Microcomputed tomography provides high accuracy congenital heart disease diagnosis in neonatal and fetal mice.

Kim Andrew J AJ   Francis Richard R   Liu Xiaoqin X   Devine William A WA   Ramirez Ricardo R   Anderton Shane J SJ   Wong Li Yin LY   Faruque Fahim F   Gabriel George C GC   Chung Wendy W   Leatherbury Linda L   Tobita Kimimasa K   Lo Cecilia W CW  

Circulation. Cardiovascular imaging 20130612 4


<h4>Background</h4>Mice are well suited for modeling human congenital heart disease (CHD), given their 4-chamber cardiac anatomy. However, mice with CHD invariably die prenatally/neonatally, causing CHD phenotypes to be missed. Therefore, we investigated the efficacy of noninvasive microcomputed tomography (micro-CT) to screen for CHD in stillborn/fetal mice. These studies were performed using chemically mutagenized mice expected to be enriched for birth defects, including CHD.<h4>Methods and re  ...[more]

Similar Datasets

| S-EPMC5552254 | biostudies-literature
| S-EPMC5691325 | biostudies-literature
| S-EPMC8008290 | biostudies-literature
| S-EPMC3612978 | biostudies-literature
| S-EPMC9905309 | biostudies-literature
2023-03-01 | GSE221349 | GEO
| S-EPMC3672155 | biostudies-literature
| S-EPMC7881192 | biostudies-literature
| S-EPMC4599542 | biostudies-literature
| S-EPMC6958889 | biostudies-literature