Shear stress, energy losses, and costs: a resolved dilemma of pulsatile cardiac assist devices.


ABSTRACT: Cardiac assist devices (CAD) cause endothelial dysfunction with considerable morbidity. Employment of pulsatile CAD remains controversial due to inadequate perfusion curves and costs. Alternatively, we are proposing a new concept of pulsatile CAD based on a fundamental revision of the entire circulatory system in correspondence with the physiopathology and law of physics. It concerns a double lumen disposable tube device that could be adapted to conventional cardiopulmonary bypass (CPB) and/or CAD, for inducing a homogenous, downstream pulsatile perfusion mode with lower energy losses. In this study, the device's prototypes were tested in a simulated conventional pediatric CPB circuit for energy losses and as a left ventricular assist device (LVAD) in ischemic piglets model for endothelial shear stress (ESS) evaluations. In conclusion and according to the study results the pulsatile tube was successfully capable of transforming a conventional CPB and/or CAD steady flow into a pulsatile perfusion mode, with nearly physiologic pulse pressure and lower energy losses. This represents a cost-effective promising method with low mortality and morbidity, especially in fragile cardiac patients.

SUBMITTER: Nour S 

PROVIDER: S-EPMC3913384 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Shear stress, energy losses, and costs: a resolved dilemma of pulsatile cardiac assist devices.

Nour Sayed S   Liu Jia J   Dai Gang G   Carbognani Daniel D   Yang Daya D   Wu Guifu G   Wang Qinmei Q   Chachques Juan Carlos JC  

BioMed research international 20140108


Cardiac assist devices (CAD) cause endothelial dysfunction with considerable morbidity. Employment of pulsatile CAD remains controversial due to inadequate perfusion curves and costs. Alternatively, we are proposing a new concept of pulsatile CAD based on a fundamental revision of the entire circulatory system in correspondence with the physiopathology and law of physics. It concerns a double lumen disposable tube device that could be adapted to conventional cardiopulmonary bypass (CPB) and/or C  ...[more]

Similar Datasets

| S-EPMC8350417 | biostudies-literature
| S-EPMC3178740 | biostudies-literature
| S-EPMC3343032 | biostudies-literature
| S-EPMC6217914 | biostudies-literature
| S-EPMC8396996 | biostudies-literature
| S-EPMC6240491 | biostudies-literature
| S-EPMC7271960 | biostudies-literature
| S-EPMC9132540 | biostudies-literature
| S-EPMC2746082 | biostudies-literature
| S-EPMC9775985 | biostudies-literature