Unknown

Dataset Information

0

Dual-beam histotripsy: a low-frequency pump enabling a high-frequency probe for precise lesion formation.


ABSTRACT: Histotripsy produces tissue fractionation through dense energetic bubble clouds generated by short, high-pressure, ultrasound pulses. When using pulses shorter than 2 cycles, the generation of these energetic bubble clouds only depends on where the peak negative pressure (P-) exceeds the intrinsic threshold of the medium (26 to 30 MPa in soft tissue with high water content). This paper investigates a strategic method for precise lesion generation in which a low-frequency pump pulse is applied to enable a sub-threshold high-frequency probe pulse to exceed the intrinsic threshold. This pump-probe method of controlling a supra-threshold volume can be called dual-beam histotripsy. A 20-element dual-frequency (500-kHz and 3-MHz elements confocally aligned) array transducer was used to generate dual-beam histotripsy pulses in red blood cell phantoms and porcine hepatic tissue specimens. The results showed that when sub-intrinsic-threshold pump (500-kHz) and probe (3-MHz) pulses were applied together, dense bubble clouds (and resulting lesions) were only generated when their peak negative pressures combined constructively to exceed the intrinsic threshold. The smallest reproducible lesion varied with the relative amplitude between the pump and probe pulses, and, with a higher proportion of the probe pulse, smaller lesions could be generated. When the propagation direction of the probe pulse relative to the pump pulse was altered, the shape of the produced lesion changed based on the region that exceeded intrinsic threshold. Because the low-frequency pump pulse is more immune to attenuation and aberrations, and the high-frequency probe pulse can provide precision in lesion formation, this dual-beam histotripsy approach would be very useful in situations in which precise lesion formation is required through a highly attenuative and aberrative medium, such as transcranial therapy. This is particularly true if a small low-attenuation acoustic window is available for the high-frequency probe transducer.

SUBMITTER: Lin KW 

PROVIDER: S-EPMC3971546 | biostudies-literature | 2014 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dual-beam histotripsy: a low-frequency pump enabling a high-frequency probe for precise lesion formation.

Lin Kuang-Wei KW   Duryea Alexander P AP   Kim Yohan Y   Hall Timothy L TL   Xu Zhen Z   Cain Charles A CA  

IEEE transactions on ultrasonics, ferroelectrics, and frequency control 20140201 2


Histotripsy produces tissue fractionation through dense energetic bubble clouds generated by short, high-pressure, ultrasound pulses. When using pulses shorter than 2 cycles, the generation of these energetic bubble clouds only depends on where the peak negative pressure (P-) exceeds the intrinsic threshold of the medium (26 to 30 MPa in soft tissue with high water content). This paper investigates a strategic method for precise lesion generation in which a low-frequency pump pulse is applied to  ...[more]

Similar Datasets

| S-EPMC4711627 | biostudies-literature
| S-EPMC6044776 | biostudies-literature
| S-EPMC5104978 | biostudies-literature
| S-EPMC3770162 | biostudies-literature
| S-EPMC6013463 | biostudies-literature
| S-EPMC8457154 | biostudies-literature
| S-EPMC5363785 | biostudies-literature
| S-EPMC3563032 | biostudies-literature
| S-EPMC7367876 | biostudies-literature
| S-EPMC5547902 | biostudies-literature