Unknown

Dataset Information

0

Automated electronic medical record sepsis detection in the emergency department.


ABSTRACT: Background. While often first treated in the emergency department (ED), identification of sepsis is difficult. Electronic medical record (EMR) clinical decision tools offer a novel strategy for identifying patients with sepsis. The objective of this study was to test the accuracy of an EMR-based, automated sepsis identification system. Methods. We tested an EMR-based sepsis identification tool at a major academic, urban ED with 64,000 annual visits. The EMR system collected vital sign and laboratory test information on all ED patients, triggering a "sepsis alert" for those with ?2 SIRS (systemic inflammatory response syndrome) criteria (fever, tachycardia, tachypnea, leukocytosis) plus ?1 major organ dysfunction (SBP ? 90 mm Hg, lactic acid ?2.0 mg/dL). We confirmed the presence of sepsis through manual review of physician, nursing, and laboratory records. We also reviewed a random selection of ED cases that did not trigger a sepsis alert. We evaluated the diagnostic accuracy of the sepsis identification tool. Results. From January 1 through March 31, 2012, there were 795 automated sepsis alerts. We randomly selected 300 cases without a sepsis alert from the same period. The true prevalence of sepsis was 355/795 (44.7%) among alerts and 0/300 (0%) among non-alerts. The positive predictive value of the sepsis alert was 44.7% (95% CI [41.2-48.2%]). Pneumonia and respiratory infections (38%) and urinary tract infection (32.7%) were the most common infections among the 355 patients with true sepsis (true positives). Among false-positive sepsis alerts, the most common medical conditions were gastrointestinal (26.1%), traumatic (25.7%), and cardiovascular (20.0%) conditions. Rates of hospital admission were: true-positive sepsis alert 91.0%, false-positive alert 83.0%, no sepsis alert 5.7%. Conclusions. This ED EMR-based automated sepsis identification system was able to detect cases with sepsis. Automated EMR-based detection may provide a viable strategy for identifying sepsis in the ED.

SUBMITTER: Nguyen SQ 

PROVIDER: S-EPMC3994640 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Automated electronic medical record sepsis detection in the emergency department.

Nguyen Su Q SQ   Mwakalindile Edwin E   Booth James S JS   Hogan Vicki V   Morgan Jordan J   Prickett Charles T CT   Donnelly John P JP   Wang Henry E HE  

PeerJ 20140410


Background. While often first treated in the emergency department (ED), identification of sepsis is difficult. Electronic medical record (EMR) clinical decision tools offer a novel strategy for identifying patients with sepsis. The objective of this study was to test the accuracy of an EMR-based, automated sepsis identification system. Methods. We tested an EMR-based sepsis identification tool at a major academic, urban ED with 64,000 annual visits. The EMR system collected vital sign and labora  ...[more]

Similar Datasets

| S-EPMC6051766 | biostudies-literature
| S-EPMC6231820 | biostudies-other
2020-01-01 | GSE119217 | GEO
| S-EPMC6877202 | biostudies-literature
| S-EPMC6029277 | biostudies-literature
| S-EPMC7205161 | biostudies-literature
| S-EPMC7708303 | biostudies-literature
| S-EPMC6295028 | biostudies-literature
| S-EPMC6921192 | biostudies-literature
| S-EPMC6579743 | biostudies-literature