Unknown

Dataset Information

0

Solid MRI contrast agents for long-term, quantitative in vivo oxygen sensing.


ABSTRACT: Targeted MRI contrast agents have proven useful in research and clinical studies for highlighting specific metabolites and biomarkers [Davies GL, et al. (2013) Chem Commun (Camb) 49(84):9704-9721] but their applicability in serial imaging is limited owing to a changing concentration postinjection. Solid enclosures have previously been used to keep the local concentration of contrast agent constant, but the need to surgically implant these devices limits their use [Daniel K, et al. (2009) Biosens Bioelectron 24(11):3252-3257]. This paper describes a novel class of contrast agent that comprises a responsive material for contrast generation and an injectable polymeric matrix for structural support. Using this principle, we have designed a contrast agent sensitive to oxygen, which is composed of dodecamethylpentasiloxane as the responsive material and polydimethylsiloxane as the matrix material. A rodent inspired-gas model demonstrated that these materials are functionally stable in vivo for at least 1 mo, which represents an order of magnitude improvement over an injection of liquid siloxane [Kodibagkar VD, et al. (2006) Magn Reson Med 55(4):743-748]. We also observed minimal adverse tissue reactions or migration of contrast agents from the initial injection site. This class of contrast agents, thus, represented a new and complementary method to monitor chronic diseases by MRI.

SUBMITTER: Liu VH 

PROVIDER: S-EPMC4020104 | biostudies-literature | 2014 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Solid MRI contrast agents for long-term, quantitative in vivo oxygen sensing.

Liu Vincent H VH   Vassiliou Christophoros C CC   Imaad Syed M SM   Cima Michael J MJ  

Proceedings of the National Academy of Sciences of the United States of America 20140421 18


Targeted MRI contrast agents have proven useful in research and clinical studies for highlighting specific metabolites and biomarkers [Davies GL, et al. (2013) Chem Commun (Camb) 49(84):9704-9721] but their applicability in serial imaging is limited owing to a changing concentration postinjection. Solid enclosures have previously been used to keep the local concentration of contrast agent constant, but the need to surgically implant these devices limits their use [Daniel K, et al. (2009) Biosens  ...[more]

Similar Datasets

| S-EPMC5441847 | biostudies-literature
| S-EPMC3586605 | biostudies-literature
| S-EPMC3170541 | biostudies-literature
| S-EPMC8030530 | biostudies-literature
| S-EPMC3508381 | biostudies-literature
| S-EPMC2723842 | biostudies-literature
| S-EPMC2692035 | biostudies-literature
| S-EPMC4979685 | biostudies-literature
| S-EPMC3032015 | biostudies-literature
| S-EPMC3857136 | biostudies-literature