Unknown

Dataset Information

0

Measurement and visualization of mass transport for the flowing atmospheric pressure afterglow (FAPA) ambient mass-spectrometry source.


ABSTRACT: Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification because of the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet.

SUBMITTER: Pfeuffer KP 

PROVIDER: S-EPMC4031277 | biostudies-literature | 2014 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Measurement and visualization of mass transport for the flowing atmospheric pressure afterglow (FAPA) ambient mass-spectrometry source.

Pfeuffer Kevin P KP   Ray Steven J SJ   Hieftje Gary M GM  

Journal of the American Society for Mass Spectrometry 20140501 5


Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be s  ...[more]

Similar Datasets

| S-EPMC3769108 | biostudies-other
| S-EPMC10424281 | biostudies-literature
| S-EPMC7603377 | biostudies-literature
| S-EPMC6651046 | biostudies-literature
| S-EPMC9142459 | biostudies-literature
| S-EPMC6339754 | biostudies-literature
| S-EPMC5628576 | biostudies-literature
| S-EPMC3715584 | biostudies-literature
2024-10-09 | GSE279139 | GEO
| S-EPMC3073421 | biostudies-literature