Unknown

Dataset Information

0

Independent value of cardiac troponin T and left ventricular global longitudinal strain in predicting all-cause mortality among stable hemodialysis patients with preserved left ventricular ejection fraction.


ABSTRACT: Using a speckle-tracking echocardiography (STE), we recently demonstrated that a left ventricular (LV) global longitudinal strain (GLS) ? -15% and the serum cardiac troponin T (cTnT) concentration are associated with mortality in stable hemodialysis patients with preserved LV ejection fraction (LVEF). In this study, we explored the relationship between cTnT and echocardiographic parameters and evaluated whether the prognostic value provided by cTnT is independent of a GLS ? -15% and vice versa. Eighty-eight stable hemodialysis patients with preserved LVEF were followed for 31 months. STE studies and measurements of cTnT were performed at baseline. CTnT concentration had a modest correlation with GLS (rs = 0.44; P < 0.001) but had a weak or nonsignificant correlation with other echocardiographic parameters. Adjusting for clinical parameters, hazard ratios for each increase of 0.01 ng/mL in cTnT, and a GLS ? -15% on mortality were 1.13 (P = 0.009) and 3.09 (P = 0.03) without significant interaction between cTnT and GLS ? -15%. In addition, an increased cTnT concentration, a GLS ? -15%, or their combination showed significant additional predictive value for mortality when included in models consisting of clinical parameters. Therefore, both cTnT and a GLS ? -15% are independent predictors of mortality and are useful for risk stratification.

SUBMITTER: Sung JM 

PROVIDER: S-EPMC4033336 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Independent value of cardiac troponin T and left ventricular global longitudinal strain in predicting all-cause mortality among stable hemodialysis patients with preserved left ventricular ejection fraction.

Sung Junne-Ming JM   Su Chi-Ting CT   Chang Yu-Tzu YT   Su Yu-Ru YR   Tsai Wei-Chuan WC   Wang Saprina P H SP   Yang Chun-Shin CS   Tsai Liang-Miin LM   Chen Jyh-Hong JH   Liu Yen-Wen YW  

BioMed research international 20140507


Using a speckle-tracking echocardiography (STE), we recently demonstrated that a left ventricular (LV) global longitudinal strain (GLS) ≥ -15% and the serum cardiac troponin T (cTnT) concentration are associated with mortality in stable hemodialysis patients with preserved LV ejection fraction (LVEF). In this study, we explored the relationship between cTnT and echocardiographic parameters and evaluated whether the prognostic value provided by cTnT is independent of a GLS ≥ -15% and vice versa.  ...[more]

Similar Datasets

| S-EPMC3805079 | biostudies-other
| S-EPMC8747922 | biostudies-literature
| S-EPMC11210017 | biostudies-literature
| S-EPMC6279198 | biostudies-other
| S-EPMC1768853 | biostudies-literature
| S-EPMC6952725 | biostudies-literature
| S-EPMC7160501 | biostudies-literature
| S-EPMC3984539 | biostudies-literature
| S-EPMC5544562 | biostudies-literature
| S-EPMC9422757 | biostudies-literature