Unknown

Dataset Information

0

A novel enzyme-linked immunosorbent assay for detection of Escherichia coli O157:H7 using immunomagnetic and beacon gold nanoparticles.


ABSTRACT: This paper presents a functional nanoparticle-enhanced enzyme-linked immunosorbent assay (FNP-ELISA) for detection of enterohemorrhagic Escherichia coli (EHEC) O157:H7. Immunomagnetic nanoparticles (IMMPs) conjugated with monoclonal anti-O157:H7 antibody were used to capture E. coli O157:H7. Beacon gold nanoparticles (B-GNPs) coated with polyclonal anti-O157:H7 and biotin single-stranded DNA (B-DNA) were then subjective to immunoreaction with E. coli O157:H7, which was followed by streptavidin-horseradish peroxidase (Strep-HRP) conjugated with B-GNPs based on a biotin-avidin system. The solutions containing E. coli O157:H7, IMMPs, B-GNPs, and Strep-HRP were collected for detecting color change. The signal was significantly amplified with detection limits of 68 CFU mL(-1) in PBS and 6.8?×?10(2) to 6.8?×?10(3) CFU mL(-1) in the food samples. The FNP-ELISA method developed in this study was two orders of magnitude more sensitive than immunomagnetic separation ELISA (IMS-ELISA) and four orders of magnitude more sensitive than C-ELISA. The entire detection process of E. coli O157:H7 lasted only 3 h, and thus FNP-ELISA is considered as a time-saving method.

SUBMITTER: Shen Z 

PROVIDER: S-EPMC4033681 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

A novel enzyme-linked immunosorbent assay for detection of Escherichia coli O157:H7 using immunomagnetic and beacon gold nanoparticles.

Shen Zhiqiang Z   Hou Nannan N   Jin Min M   Qiu Zhigang Z   Wang Jingfeng J   Zhang Bin B   Wang Xinwei X   Wang Jie J   Zhou Dongsheng D   Li Junwen J  

Gut pathogens 20140520


This paper presents a functional nanoparticle-enhanced enzyme-linked immunosorbent assay (FNP-ELISA) for detection of enterohemorrhagic Escherichia coli (EHEC) O157:H7. Immunomagnetic nanoparticles (IMMPs) conjugated with monoclonal anti-O157:H7 antibody were used to capture E. coli O157:H7. Beacon gold nanoparticles (B-GNPs) coated with polyclonal anti-O157:H7 and biotin single-stranded DNA (B-DNA) were then subjective to immunoreaction with E. coli O157:H7, which was followed by streptavidin-h  ...[more]

Similar Datasets

| S-EPMC5301989 | biostudies-literature
| S-EPMC2886893 | biostudies-other
| S-EPMC9326611 | biostudies-literature
| S-EPMC120007 | biostudies-literature
| S-EPMC4249723 | biostudies-literature
| S-EPMC5795359 | biostudies-literature
| S-EPMC2976089 | biostudies-literature
| S-EPMC4239385 | biostudies-literature
| S-EPMC3322434 | biostudies-literature
| S-EPMC9887224 | biostudies-literature