Unknown

Dataset Information

0

Short-term effects of noisy pressure support ventilation in patients with acute hypoxemic respiratory failure.


ABSTRACT: This study aims at comparing the very short-term effects of conventional and noisy (variable) pressure support ventilation (PSV) in mechanically ventilated patients with acute hypoxemic respiratory failure.Thirteen mechanically ventilated patients with acute hypoxemic respiratory failure were enrolled in this monocentric, randomized crossover study. Patients were mechanically ventilated with conventional and noisy PSV, for one hour each, in random sequence. Pressure support was titrated to reach tidal volumes approximately 8 mL/kg in both modes. The level of positive end-expiratory pressure and fraction of inspired oxygen were kept unchanged in both modes. The coefficient of variation of pressure support during noisy PSV was set at 30%. Gas exchange, hemodynamics, lung functional parameters, distribution of ventilation by electrical impedance tomography, breathing patterns and patient-ventilator synchrony were analyzed.Noisy PSV was not associated with any adverse event, and was well tolerated by all patients. Gas exchange, hemodynamics, respiratory mechanics and spatial distribution of ventilation did not differ significantly between conventional and noisy PSV. Noisy PSV increased the variability of tidal volume (24.4?±?7.8% vs. 13.7?±?9.1%, P?<0.05) and was associated with a reduced number of asynchrony events compared to conventional PSV (5 (0 to 15)/30 min vs. 10 (1 to 37)/30 min, P?<0.05).In the very short term, noisy PSV proved safe and feasible in patients with acute hypoxemic respiratory failure. Compared to conventional PSV, noisy PSV increased the variability of tidal volumes, and was associated with improved patient-ventilator synchrony, at comparable levels of gas exchange.ClinicialTrials.gov, NCT00786292.

SUBMITTER: Spieth PM 

PROVIDER: S-EPMC4056040 | biostudies-literature | 2013 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Short-term effects of noisy pressure support ventilation in patients with acute hypoxemic respiratory failure.

Spieth Peter M PM   Güldner Andreas A   Huhle Robert R   Beda Alessandro A   Bluth Thomas T   Schreiter Dierk D   Ragaller Max M   Gottschlich Birgit B   Kiss Thomas T   Jaber Samir S   Pelosi Paolo P   Koch Thea T   Gama de Abreu Marcelo M  

Critical care (London, England) 20131031 5


<h4>Introduction</h4>This study aims at comparing the very short-term effects of conventional and noisy (variable) pressure support ventilation (PSV) in mechanically ventilated patients with acute hypoxemic respiratory failure.<h4>Methods</h4>Thirteen mechanically ventilated patients with acute hypoxemic respiratory failure were enrolled in this monocentric, randomized crossover study. Patients were mechanically ventilated with conventional and noisy PSV, for one hour each, in random sequence. P  ...[more]

Similar Datasets

| S-EPMC6114230 | biostudies-literature
| S-EPMC9994217 | biostudies-literature
| S-EPMC9422941 | biostudies-literature
| S-EPMC7871131 | biostudies-literature
| S-EPMC5537116 | biostudies-literature
| S-EPMC4139286 | biostudies-literature
| S-EPMC5748128 | biostudies-literature
| S-EPMC6692798 | biostudies-other
| S-EPMC9072760 | biostudies-literature
| S-EPMC6154743 | biostudies-literature