Unknown

Dataset Information

0

Interventional heart wall motion analysis with cardiac C-arm CT systems.


ABSTRACT: Today, quantitative analysis of three-dimensional (3D) dynamics of the left ventricle (LV) cannot be performed directly in the catheter lab using a current angiographic C-arm system, which is the workhorse imaging modality for cardiac interventions. Therefore, myocardial wall analysis is completely based on the 2D angiographic images or pre-interventional 3D/4D imaging. In this paper, we present a complete framework to study the ventricular wall motion in 4D (3D+t) directly in the catheter lab. From the acquired 2D projection images, a dynamic 3D surface model of the LV is generated, which is then used to detect ventricular dyssynchrony. Different quantitative features to evaluate LV dynamics known from other modalities (ultrasound, magnetic resonance imaging) are transferred to the C-arm CT data. We use the ejection fraction, the systolic dyssynchrony index a 3D fractional shortening and the phase to maximal contraction (?i, max) to determine an indicator of LV dyssynchrony and to discriminate regionally pathological from normal myocardium. The proposed analysis tool was evaluated on simulated phantom LV data with and without pathological wall dysfunctions. The LV data used is publicly available online at https://conrad.stanford.edu/data/heart. In addition, the presented framework was tested on eight clinical patient data sets. The first clinical results demonstrate promising performance of the proposed analysis tool and encourage the application of the presented framework to a larger study in clinical practice.

SUBMITTER: Muller K 

PROVIDER: S-EPMC4067952 | biostudies-literature | 2014 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Interventional heart wall motion analysis with cardiac C-arm CT systems.

Müller Kerstin K   Maier Andreas K AK   Zheng Yefeng Y   Wang Yang Y   Lauritsch Günter G   Schwemmer Chris C   Rohkohl Christopher C   Hornegger Joachim J   Fahrig Rebecca R  

Physics in medicine and biology 20140415 9


Today, quantitative analysis of three-dimensional (3D) dynamics of the left ventricle (LV) cannot be performed directly in the catheter lab using a current angiographic C-arm system, which is the workhorse imaging modality for cardiac interventions. Therefore, myocardial wall analysis is completely based on the 2D angiographic images or pre-interventional 3D/4D imaging. In this paper, we present a complete framework to study the ventricular wall motion in 4D (3D+t) directly in the catheter lab.  ...[more]

Similar Datasets

| S-EPMC4110354 | biostudies-literature
| S-EPMC5412916 | biostudies-literature
| S-EPMC8592109 | biostudies-literature
| S-EPMC5984644 | biostudies-literature
| S-EPMC4969567 | biostudies-other
| S-EPMC3161502 | biostudies-other
| S-EPMC6237624 | biostudies-literature
| S-EPMC6323633 | biostudies-literature
| S-EPMC3396707 | biostudies-other
| S-EPMC4008764 | biostudies-other