Rapid response oxygen-sensing nanofibers.


ABSTRACT: Molecular oxygen has profound effects on cell and tissue viability. Relevant sensor forms that can rapidly determine dissolved oxygen levels under biologically relevant conditions provide critical metabolic information. Using 0.5 ?m diameter electrospun polycaprolactone (PCL) fiber containing an oxygen-sensitive probe, tris (4,7-diphenyl-1,10-phenanthroline) ruthenium(II) dichloride, we observed a response time of 0.9±0.12 s while the t95 for the corresponding film was more than two orders of magnitude greater. Interestingly, the response and recovery times of slightly larger diameter PCL fibers were 1.79±0.23 s and 2.29±0.13 s, respectively, while the recovery time was not statistically different likely due to the more limited interactions of nitrogen with the polymer matrix. A more than 10-fold increase in PCL fiber diameter reduces oxygen sensitivity while having minor effects on response time; conversely, decreases in fiber diameter to less than 0.5 ?m would likely decrease response times even further. In addition, a 50°C heat treatment of the electrospun fiber resulted in both increased Stern-Volmer slope and linearity likely due to secondary recrystallization that further homogenized the probe microenvironment. At exposure times up to 3600 s in length, photobleaching was observed but was largely eliminated by the use of either polyethersulfone (PES) or a PES-PCL core-shell composition. However, this resulted in 2- and 3-fold slower response times. Finally, even the non-core shell compositions containing the Ru oxygen probe result in no apparent cytotoxicity in representative glioblastoma cell populations.

SUBMITTER: Xue R 

PROVIDER: S-EPMC4068958 | biostudies-literature | 2013 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Rapid response oxygen-sensing nanofibers.

Xue Ruipeng R   Behera Prajna P   Viapiano Mariano S MS   Lannutti John J JJ  

Materials science & engineering. C, Materials for biological applications 20130422 6


Molecular oxygen has profound effects on cell and tissue viability. Relevant sensor forms that can rapidly determine dissolved oxygen levels under biologically relevant conditions provide critical metabolic information. Using 0.5 μm diameter electrospun polycaprolactone (PCL) fiber containing an oxygen-sensitive probe, tris (4,7-diphenyl-1,10-phenanthroline) ruthenium(II) dichloride, we observed a response time of 0.9±0.12 s while the t95 for the corresponding film was more than two orders of ma  ...[more]

Similar Datasets

| S-EPMC4278692 | biostudies-literature
| S-EPMC2849644 | biostudies-literature
2004-03-11 | GSE1079 | GEO
| S-EPMC8153741 | biostudies-literature
| S-EPMC8028015 | biostudies-literature
2010-06-09 | E-GEOD-1079 | biostudies-arrayexpress
| S-EPMC5134516 | biostudies-literature
| S-EPMC6414850 | biostudies-literature
| S-EPMC4457464 | biostudies-other
| S-EPMC7859936 | biostudies-literature