Unknown

Dataset Information

0

Selected reaction monitoring (SRM) mass spectrometry without isotope labeling can be used for rapid protein quantification.


ABSTRACT: The validation of putative biomarker candidates has become the major bottle-neck in protein biomarker development. Conventional immunoaffinity methods are limited by the availability of antibodies and kits. Here we demonstrate the feasibility of using selected reaction monitoring (SRM) without isotope labeling to achieve fast and reproducible quantification of serum proteins. The SRM/MRM assays for three standard serum proteins, including ceruloplasmin (CP), serum aymloid A (SAA) and sex hormone binding globulin (SHBG), have good linear ranges, generally 10(3) to 10(4) . There are almost perfect correlations between SRM intensities and the loaded peptide amounts (R(2) is usually ~0.99). Our data suggest that SRM/MRM is able to quantify proteins within the range of 0.2-2 fmol, which is comparable to the commercial ELISA/LUMINEX kits for these proteins. Excellent correlations between SRM/MRM and ELISA/LUMINEX assays were observed for SAA and SHBG (R(2)=0.928 and 0.851, respectively). However, the correlation between SRM/MRM and ELISA for CP is less desirable (R(2)=0.565). The reproducibility for SRM/MRM assays is generally very good but may depend on the proteins/peptides being analyzed (R(2)=0.931 and 0.882 for SAA and SHBG, and 0.723 for CP). The SRM/MRM assay without isotope labeling is a rapid and useful method for protein biomarker validation in a modest number of samples and is especially useful when other assays such as ELISA or LUMINEX are not available.

SUBMITTER: Zhi W 

PROVIDER: S-EPMC4121859 | biostudies-literature | 2011 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Selected reaction monitoring (SRM) mass spectrometry without isotope labeling can be used for rapid protein quantification.

Zhi Wenbo W   Wang Meiyao M   She Jin-Xiong JX  

Rapid communications in mass spectrometry : RCM 20110601 11


The validation of putative biomarker candidates has become the major bottle-neck in protein biomarker development. Conventional immunoaffinity methods are limited by the availability of antibodies and kits. Here we demonstrate the feasibility of using selected reaction monitoring (SRM) without isotope labeling to achieve fast and reproducible quantification of serum proteins. The SRM/MRM assays for three standard serum proteins, including ceruloplasmin (CP), serum aymloid A (SAA) and sex hormone  ...[more]

Similar Datasets

| S-EPMC5031629 | biostudies-literature
| S-EPMC3567869 | biostudies-literature
| S-EPMC4692538 | biostudies-literature
| S-EPMC3763905 | biostudies-literature
| S-EPMC3108844 | biostudies-literature
| S-EPMC3866616 | biostudies-literature
| S-EPMC3005404 | biostudies-literature
2016-08-10 | PXD004413 | Pride
| S-EPMC7757672 | biostudies-literature
| S-EPMC3466133 | biostudies-literature