Comparison of cerebral blood flow acquired by simultaneous [15O]water positron emission tomography and arterial spin labeling magnetic resonance imaging.


ABSTRACT: Until recently, no direct comparison between [(15)O]water positron emission tomography (PET) and arterial spin labeling (ASL) for measuring cerebral blood flow (CBF) was possible. With the introduction of integrated, hybrid magnetic resonance (MR)-PET scanners, such a comparison becomes feasible. This study presents results of CBF measurements recorded simultaneously with [(15)O]water and ASL. A 3T MR-BrainPET scanner was used for the simultaneous acquisition of pseudo-continuous ASL (pCASL) magnetic resonance imaging (MRI) and [(15)O]water PET. Quantitative CBF values were compared in 10 young healthy male volunteers at baseline conditions. A statistically significant (P<0.05) correlation was observed between the two modalities; the whole-brain CBF values determined with PET and pCASL were 43.3±6.1?mL and 51.9±7.1?mL per 100?g per minute, respectively. The gray/white matter (GM/WM) ratio of CBF was 3.0 for PET and 3.4 for pCASL. A paired t-test revealed differences in regional CBF between ASL and PET with higher ASL-CBF than PET-CBF values in cortical areas. Using an integrated, hybrid MR-PET a direct simultaneous comparison between ASL and [(15)O]water PET became possible for the first time so that temporal, physiologic, and functional variations were avoided. Regional and individual differences were found despite the overall similarity between ASL and PET, requiring further detailed investigations.

SUBMITTER: Zhang K 

PROVIDER: S-EPMC4126098 | biostudies-literature | 2014 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of cerebral blood flow acquired by simultaneous [15O]water positron emission tomography and arterial spin labeling magnetic resonance imaging.

Zhang Ke K   Herzog Hans H   Mauler Jörg J   Filss Christian C   Okell Thomas W TW   Kops Elena Rota ER   Tellmann Lutz L   Fischer Thomas T   Brocke Burkhard B   Sturm Walter W   Coenen Heinz H HH   Shah N Jon NJ  

Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism 20140521 8


Until recently, no direct comparison between [(15)O]water positron emission tomography (PET) and arterial spin labeling (ASL) for measuring cerebral blood flow (CBF) was possible. With the introduction of integrated, hybrid magnetic resonance (MR)-PET scanners, such a comparison becomes feasible. This study presents results of CBF measurements recorded simultaneously with [(15)O]water and ASL. A 3T MR-BrainPET scanner was used for the simultaneous acquisition of pseudo-continuous ASL (pCASL) mag  ...[more]

Similar Datasets

| S-EPMC4635240 | biostudies-literature
| S-EPMC6430723 | biostudies-literature
| S-EPMC7161423 | biostudies-literature
| S-EPMC3298573 | biostudies-other
| S-EPMC6311663 | biostudies-literature
| S-EPMC7419408 | biostudies-literature
| S-EPMC7370620 | biostudies-literature
2015-02-09 | E-MTAB-3175 | biostudies-arrayexpress
| S-EPMC2268792 | biostudies-literature
| S-EPMC11346363 | biostudies-literature