Assessment of prosthesis alignment after revision total knee arthroplasty using EOS 2D and 3D imaging: a reliability study.


ABSTRACT: INTRODUCTION: A new low-dose X-ray device, called EOS, has been introduced for determining lower-limb alignment in 2D and 3D. Reliability has not yet been assessed when using EOS on lower limbs containing a knee prosthesis. Therefore purpose of this study was to determine intraobserver and interobserver reliability of EOS 2D and 3D knee prosthesis alignment measurements after revision total knee arthroplasty (rTKA). METHODS: Forty anteroposterior and lateral images of 37 rTKA patients were included. Two observers independently performed measurements on these images twice. Varus/valgus angles were measured in 2D (VV2D) and 3D (VV3D). Intraclass correlation coefficients and the Bland and Altman method were used to determine reliability. T-tests were used to test potential differences. RESULTS: Intraobserver and interobserver reliability were excellent for VV2D and VV3D. No significant difference or bias between the first and second measurements or the two observers was found. A significant mean and absolute difference of respectively 1.00° and 1.61° existed between 2D and 3D measurements. CONCLUSIONS: EOS provides reliable varus/valgus measurements in 2D and 3D for the alignment of the knee joint with a knee prosthesis. However, significant differences exist between varus/valgus measurements in 2D and 3D.

SUBMITTER: Meijer MF 

PROVIDER: S-EPMC4172435 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Assessment of prosthesis alignment after revision total knee arthroplasty using EOS 2D and 3D imaging: a reliability study.

Meijer Marrigje F MF   Boerboom Alexander L AL   Stevens Martin M   Bulstra Sjoerd K SK   Reininga Inge H F IH  

PloS one 20140923 9


<h4>Introduction</h4>A new low-dose X-ray device, called EOS, has been introduced for determining lower-limb alignment in 2D and 3D. Reliability has not yet been assessed when using EOS on lower limbs containing a knee prosthesis. Therefore purpose of this study was to determine intraobserver and interobserver reliability of EOS 2D and 3D knee prosthesis alignment measurements after revision total knee arthroplasty (rTKA).<h4>Methods</h4>Forty anteroposterior and lateral images of 37 rTKA patien  ...[more]

Similar Datasets

| S-EPMC8167321 | biostudies-literature
| S-EPMC7461261 | biostudies-literature
| S-EPMC8666608 | biostudies-literature
| S-EPMC8428977 | biostudies-literature
| S-EPMC10514418 | biostudies-literature
| S-EPMC8666599 | biostudies-literature
| S-EPMC9867950 | biostudies-literature
| S-EPMC4165843 | biostudies-literature
2010-04-12 | E-GEOD-21164 | biostudies-arrayexpress
| S-EPMC4513597 | biostudies-literature