Dark-field illumination on zero-mode waveguide/microfluidic hybrid chip reveals T4 replisomal protein interactions.


ABSTRACT: The ability of zero-mode waveguides (ZMWs) to guide light energy into subwavelength-diameter cylindrical nanoapertures has been exploited for single-molecule fluorescence studies of biomolecules at micromolar concentrations, the typical dissociation constants for biomolecular interactions. Although epi-fluorescence microscopy is now adopted for ZMW-based imaging as an alternative to the commercialized ZMW imaging platform, its suitability and performance awaits rigorous examination. Here, we present conical lens-based dark-field fluorescence microscopy in combination with a ZMW/microfluidic chip for single-molecule fluorescence imaging. We demonstrate that compared to epi-illumination, the dark-field configuration displayed diminished background and noise and enhanced signal-to-noise ratios. This signal-to-noise ratio for imaging using the dark-field setup remains essentially unperturbed by the presence of background fluorescent molecules at micromolar concentration. Our design allowed single-molecule FRET studies that revealed weak DNA-protein and protein-protein interactions found with T4 replisomal proteins.

SUBMITTER: Zhao Y 

PROVIDER: S-EPMC4183369 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dark-field illumination on zero-mode waveguide/microfluidic hybrid chip reveals T4 replisomal protein interactions.

Zhao Yanhui Y   Chen Danqi D   Yue Hongjun H   Spiering Michelle M MM   Zhao Chenglong C   Benkovic Stephen J SJ   Huang Tony Jun TJ  

Nano letters 20140324 4


The ability of zero-mode waveguides (ZMWs) to guide light energy into subwavelength-diameter cylindrical nanoapertures has been exploited for single-molecule fluorescence studies of biomolecules at micromolar concentrations, the typical dissociation constants for biomolecular interactions. Although epi-fluorescence microscopy is now adopted for ZMW-based imaging as an alternative to the commercialized ZMW imaging platform, its suitability and performance awaits rigorous examination. Here, we pre  ...[more]

Similar Datasets

| S-EPMC4440521 | biostudies-other
| S-EPMC7089978 | biostudies-literature
| S-EPMC3397148 | biostudies-literature
| S-EPMC7031520 | biostudies-literature
| S-EPMC5527089 | biostudies-literature
| S-EPMC2234111 | biostudies-literature
| S-EPMC6491601 | biostudies-literature
| S-EPMC8391745 | biostudies-literature
| S-EPMC4918833 | biostudies-other
| S-EPMC4466792 | biostudies-literature