Outpatient glycemic control with a bionic pancreas in type 1 diabetes.


ABSTRACT: The safety and effectiveness of automated glycemic management have not been tested in multiday studies under unrestricted outpatient conditions.In two random-order, crossover studies with similar but distinct designs, we compared glycemic control with a wearable, bihormonal, automated, "bionic" pancreas (bionic-pancreas period) with glycemic control with an insulin pump (control period) for 5 days in 20 adults and 32 adolescents with type 1 diabetes mellitus. The automatically adaptive algorithm of the bionic pancreas received data from a continuous glucose monitor to control subcutaneous delivery of insulin and glucagon.Among the adults, the mean plasma glucose level over the 5-day bionic-pancreas period was 138 mg per deciliter (7.7 mmol per liter), and the mean percentage of time with a low glucose level (<70 mg per deciliter [3.9 mmol per liter]) was 4.8%. After 1 day of automatic adaptation by the bionic pancreas, the mean (±SD) glucose level on continuous monitoring was lower than the mean level during the control period (133±13 vs. 159±30 mg per deciliter [7.4±0.7 vs. 8.8±1.7 mmol per liter], P<0.001) and the percentage of time with a low glucose reading was lower (4.1% vs. 7.3%, P=0.01). Among the adolescents, the mean plasma glucose level was also lower during the bionic-pancreas period than during the control period (138±18 vs. 157±27 mg per deciliter [7.7±1.0 vs. 8.7±1.5 mmol per liter], P=0.004), but the percentage of time with a low plasma glucose reading was similar during the two periods (6.1% and 7.6%, respectively; P=0.23). The mean frequency of interventions for hypoglycemia among the adolescents was lower during the bionic-pancreas period than during the control period (one per 1.6 days vs. one per 0.8 days, P<0.001).As compared with an insulin pump, a wearable, automated, bihormonal, bionic pancreas improved mean glycemic levels, with less frequent hypoglycemic episodes, among both adults and adolescents with type 1 diabetes mellitus. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov numbers, NCT01762059 and NCT01833988.).

SUBMITTER: Russell SJ 

PROVIDER: S-EPMC4183762 | biostudies-literature | 2014 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Outpatient glycemic control with a bionic pancreas in type 1 diabetes.

Russell Steven J SJ   El-Khatib Firas H FH   Sinha Manasi M   Magyar Kendra L KL   McKeon Katherine K   Goergen Laura G LG   Balliro Courtney C   Hillard Mallory A MA   Nathan David M DM   Damiano Edward R ER  

The New England journal of medicine 20140615 4


<h4>Background</h4>The safety and effectiveness of automated glycemic management have not been tested in multiday studies under unrestricted outpatient conditions.<h4>Methods</h4>In two random-order, crossover studies with similar but distinct designs, we compared glycemic control with a wearable, bihormonal, automated, "bionic" pancreas (bionic-pancreas period) with glycemic control with an insulin pump (control period) for 5 days in 20 adults and 32 adolescents with type 1 diabetes mellitus. T  ...[more]

Similar Datasets

| S-EPMC8546273 | biostudies-literature
| S-EPMC3476884 | biostudies-literature
| S-EPMC10028490 | biostudies-literature
| S-EPMC4010702 | biostudies-literature
| S-EPMC4799495 | biostudies-literature
2016-07-15 | ST000421 | MetabolomicsWorkbench
| S-EPMC2518008 | biostudies-other
| S-EPMC6196833 | biostudies-other
| S-EPMC11005033 | biostudies-literature
| S-EPMC5358809 | biostudies-literature